Problem solving guide
The interior drum lighting fails to
function.
The bulb may be defective.
Replace it as follows:
Switch off the machine or disconnect
from the mains supply.
Open the door.
Use a 19 mm spanner to unscrew
the plastic cover inside the drum
above the door.
The light bulb must not exceed the
maximum wattage quoted on the
data plate and the plastic light cover.
Replace the bulb and the plastic
cover.
The cover must be fixed securely, as
otherwise moisture may seep in and
cause a short-circuit.
The temperature-resistant bulb should
only be ordered from your Miele Dealer
or the Service Dept.
Get other manuals https://www.bkmanuals.com
After-sales service
In the event of any faults which cannot
be remedied, or if the appliance is
under guarantee, please contact:
– your Miele Dealer or
– the nearest Miele Service Depart-
ment (see back cover for the ad-
dress).
When contacting the Service Depart-
ment, please quote the Model and Ser-
ial nos. of your appliance, both of
which are shown on the data plate on
the right hand side below the opening
to the drum.