  • Page 1 LITHIUM LITHIUM PRO LITHIUM PRO C12-100XLi C12-100XSLi C12-200XLi USER MANUAL...
  • Page 2 Any information provided in or omitted from this user manual in any circumstances resulting in incidental or consequential damages or injuries is the responsibility of the consumer and does not constitute additional liability of Century Yuasa Batteries Pty Ltd. LITHIUM...
  • Page 3: Table Of Contents

    Table of Contents 1. Introduction ..........4 1.1 Product Description ......4 1.2 Terminology .......... 5 2. Safety ............6 3. Handling and Installation ......7 4. Operating Use ..........8 4.1 Operating conditions......8 4.2 Bluetooth connection ......9 4.3 Charging ..........
  • Page 4: Introduction

    1. Introduction 1.1 Product Description The Century Lithium Pro is a 12.8V lithium-ion battery incorporating Lithium Iron Phosphate (LFP or LiFePO4) technology and is designed for recreational cyclic applications. It contains 4 or 8 cells connected in series and in a parallel where applicable, equipped with an internal battery management system (BMS) to monitor each single prismatic cell for correct operation of the battery, as well as the loads and charge source that are connected to the battery.
  • Page 5: Terminology

    Components & Construction (Example of C12-100XLi shown) 1. Handle 2. Positive terminal, M8 nut insert 3. Negative terminal, M8 nut insert 4. Top cover: Flame Retardant ABS/PC 5. Positive connecting copper bar 6. Epoxy board Insulator 7. Negative connecting copper bar - Module to BMS 8.
  • Page 6: Safety

    The Century Lithium Pro LFP battery is designed with an integrated BMS to prevent internal damage to the battery under various conditions. When this occurs in connected equipment, power can be abruptly interrupted to the system which may cause undesirable consequence.
  • Page 7: Handling And Installation

    If the charger trips out, reset the charger until charging continues normally. For best result, each battery should be charged individually before being connected in series or parallel. Contact Century Yuasa Batteries for any further assistance. LITHIUM...
  • Page 8: Operating Use

    4.1 Operating Conditions The Century LFP battery is in sleep mode when not in use to reduce self-discharge. It will go into sleep mode after 24 hours when the charge or discharge current is below 1A.
  • Page 9: Bluetooth Connection

    4.2 Bluetooth Connection The Century Lithium Pro battery has an integrated wireless Bluetooth monitoring function. The Century Lithium Pro Bluetooth App is available for iOS and Android portable smart devices and can be downloaded from Apple App Store or Google Play Store...
  • Page 10 a. Search the battery from the listed battery Bluetooth ID(s) on the smart device, then toggle it ON: Pairing Established b. Scan the QR code on the battery and the battery Bluetooth ID will appear: Pairing Established The Bluetooth Monitoring System provides point to point connection. Only one battery can be connected to one device at a time.
  • Page 11 4.2.2 Using the App. a. After connecting, touch the paired battery name and it will bring up the ‘Basic Info’ screen. This screen shows the SOC in percentage; battery voltage; battery capacity; battery status (standby, charge, or discharge); and battery state of health (good, or service – if below 80% initial capacity) b.
  • Page 12 c. Touching “ ” icon on the ‘Basic Info’ screen will bring up the ‘Alarm’ screen. This screen displays the BMS protection function. Automatic Safety Shutoff and Restart C12-100XLi BMS Function Automatic Shutoff Recovery and Automatic Restart Over Charge Voltage Cell ≥3.7V or Battery ≥14.8V;...
  • Page 13 C12-100XSLi BMS Function Automatic Shutoff Recovery and Automatic Restart Over Charge Voltage Cell ≥3.7V or Battery ≥14.8V; 1S max Cell ≤3.45V or Battery ≤13.8V Over Discharge Voltage Cell ≤2.5V or Battery ≤10.0V; 1S max Cell ≥2.8V or Battery ≥11.2V Over Charge Current...
  • Page 14 d. Touching the “ ” icon on any of the screen will bring up the ‘Menu’ screen. Notification preferences can be set up on the smart device. CYB contact details, App information and user manual can be located in this area. LITHIUM LITHIUM PRO LITHIUM PRO...
  • Page 15: Charging

    4.3 Charging CHARGING CHARACTERISTICS 14.9 14.4 13.9 13.4 0.1C 0.5C 0.2C 12.9 12.4 11.9 Capacity (%) • The battery must be fully charged before first use. • Ensure charging voltage does not exceed 14.6V. 14.4V is recommended (refer to product spec sheets in case of exception).
  • Page 16: Discharging

    • Constant current constant voltage charging (CCCV) is recommended for LFP batteries. Refer to diagram below for illustration: 4.4. Discharging • Do not exceed the maximum discharge current as specified in the data sheet. • Avoid discharging the LFP battery at its maximum current (1C) several times in succession, as this may cause the BMS to cut out.
  • Page 17: Troubleshooting

    5. Troubleshooting SIGN POSSIBLE CAUSES CORRECTIVE ACTIONS The charging voltage is lower than 14.4V, and the battery charging capacity is less than the rated Use the standard charge voltage Ampere-Hour The load is too high, and the battery ends Reduce load wattage discharging prematurely The cell over-voltage protection has been triggered Reduce the charge voltage (eg.
  • Page 18 5. Troubleshooting continued SIGN POSSIBLE CAUSES CORRECTIVE ACTIONS Recharge the battery in time and confirm The battery is over-discharged below 10V and is that the battery can be switched on lower than the working voltage of the BMS, the normally. If the battery cannot be turned BMS cannot work normally on again, replace the battery BMS power supply line is damaged, BMS cannot...
  • Page 19: Care & Maintenance

    • Check battery cables and connections are firmly secure. • Check the battery state of charge (SOC) regularly. When not in use the Century Lithium Pro battery will partially self-discharge. • Depending on the charging profile used, overtime the series and parallel configured batteries may not be equally charged.
  • Page 20: Transportation

    8. Transportation • Century Lithium Pro batteries are packed by the manufacturer to comply with all applicable national transportation regulations. • If the battery is not installed, it must be transported in the original packaging or equivalent material. • It is recommended that the battery should be below 60% SOC during transportation.
  • Page 21 NOTES LITHIUM LITHIUM PRO LITHIUM PRO ADVANCED LiFePO4 TECHNOLOGY...