Operation: Refrigeration - Scotsman NDE750 Service Manual

Scotsman nde750 ice machine: user guide
Table of Contents

Advertisement

OPERATION: Refrigeration

Beginning at the compressor, the refrigerant is
compressed into a high temperature gas. The
discharge line directs this gas to the condenser. At
the condenser (air or water cooled) the gas is
cooled by either air or water and it then condenses
into a liquid. This high pressure liquid then goes
through the liquid line to the expansion valve.
The thermostatic expansion valve meters liquid
refrigerant into the evaporator, the volume of liquid
refrigerant depending upon the temperature of the
evaporator; warmer evaporators get more
refrigerant and colder evaporators get less.
LIQUID LINE
CONDENSER
REFRIGERATION SCHEMATIC
(AIR COOLED SHOWN)
DISCHARGE
FAN MOTOR
December 1993
At the evaporator, the refrigerant enters an area of
relatively low pressure, where it can easily "boil off"
or evaporate. As it evaporates, it absorbs heat
from the evaporator and whatever is in contact
with it (such as the water inside it). After the
evaporator, the refrigerant, now a low pressure
vapor, goes through the suction line back to
compressor, where the cycle is repeated.
SUCTION LINE
LINE
COMPRESSOR
Page 13
NDE750
THERMOSTATIC
EXPANSION VALVE
EVAPORATOR