Information @ 90
Typical Suction Pressure
35 PSIG
·
Typical Discharge Pressure
260 PSIG
·
Minimum Discharge pressure (low temps)
180 PSIG
·
Typical Compressor Amps
Single Phase = 4.3
·
Three Phase = 2.8
·
Low Pressure (pump down) Control
Cut in 30
·
·
Cut out 15
High Pressure Cut Out - Automatic Reset
Cut in 350
·
Cut out 450
·
o
o
F. air and 70
F. Water: