NME954R & FME1204R

FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES
Water Inlet
Connect a cold potable water supply
Water Inlet
to the ice machine. Use 3/8" O.D.
3/8" Male Flare
copper tubing and connect it to the
3/8" male flare at the back of the
cabinet.
Install a hand valve near the machine
Field Supplied
to control the water supply.
Water Filter
Drains
Hand Shut
The cabinet has a ¾" FPT drain.
Vent Ice
Off Valve
connection. The drain is at the back of
Maker
the cabinet, the drain line is of the
Drain, 3/4"
gravity type, and 1/4 inch per foot fall
FPT
is an acceptable pitch for the drain
tubing. There should be a vent at the
highest point of the drain line, and the
ideal drain receptacle would be a
trapped and vented floor drain. Use
Connect To
only ¾" rigid tubing.
Cold Water
Storage Bin: Install a separate
gravity drain to the ice storage bin.
Insulation of this drain line is
recommended.
Vent Bin Drain
3/4" FPT
Floor Drain
January 2000