MAINTENANCE
1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
RESERVOIR
CLEAN THE
WATER LEVEL
SENSOR
/////////////////////////////
CAUTION: THE
TIMP IS MADE OF
GLASS
///////////////////////////////
3. The bearing in the breaker should also be
checked at least two times per year.
Check the bearing by:
pushing the bail clamp back and removing the
ice chute cover
unscrewing the ice sweep
unscrewing the breaker cover
unscrewing the auger stud
Electrical Shock Hazard
Electrical shock can cause
personal injury.
Disconnect electrical
power before beginning.
SLIDE ICE
LEVEL
CONTROLS OUT
OF CHUTE
CLEAN THE ICE
LEVEL CONTROL
SENSORS
Inspect the assembly, looking for wear.
See Removal and Replacement to replace bearing
or seals. Reverse to reassemble.
4. Check and tighten all bolts and screws.