Eclipseä 600, 800, 1000

Water and Drain

Right Draining: Remove vinyl hose from barbed
fitting at drain fitting. Locate alternate vinyl hose.
Attach to barbed fitting and insert barbed fitting
from the original hose into outlet. Connect ¾" PVC
to the PVC fitting.
Back Draining: Either connect a vinyl hose to the
barbed fitting or connect PVC directly into the ¾"
FPT drain fitting.
Back View, Shown Set Up For Back Draining
Drain
Fitting
Vinyl Tube
for Right
Draining
Back View, Drain Tubing Installed for Right Side Drain
April 2002
No external drain vent is required, venting is
internally provided for.
Note: External drain tubing must be supported to
insure that it does not move and kink the internal
rubber tube.
Water Supply: Connect a supply of cold, potable
water to the 3/8" fitting on the right side of the
cabinet. A male flare fitting is on the unit.
Note: This is an NSF listed ice machine and
contains provisions for back-flow prevention in its
design. No external back flow preventer is
required.
Drain: Connect rigid drain tubing to the reservoir
drain fitting on the right side of the cabinet. Route
the drain either out the back, under the unit
(through the notch in the base) to the left side or to
the right side. A vent is built into the unit, so no
external vent is required.
Run the drain tubing to the building drain. Do not
"Tee" into any other drain, including the bin or
dispenser drain.
Barb-to-Pipe
Thread Fitting
FPT-to-PVC Fitting