Rinnai RHFE-263FA II Conversion Manual

Gas direct vent wall furnace
Hide thumbs Also See for RHFE-263FA II:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

⇒  for the conversion from
Natural Gas (NG) to Liquid
Propane Gas (LPG)
⇒  for the conversion from
Liquid Propane Gas (LPG) to
Natural Gas (NG)
⇒  for adjustments at high altitude
(greater than 2000 ft / 610m)
WARNING
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal
injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of
the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit.
C onversion Manual f or the
RHFE-263FAⅡ  
Energysaver
Gas Direct V ent W a ll Furnace
English
Technical Data................................. 2
High Altitude ................................... 2
Conversion Procedure .................... 3
Parts List........................................ 11
Données Techniques....................... 7
Haute Altitude ................................. 7
Procédure de conversion ............... 8
Liste des Pièces............................ 11

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RHFE-263FA II

  • Page 1: Table Of Contents

    C onversion Manual f or the RHFE-263FAⅡ   Energysaver Gas Direct V ent W a ll Furnace ⇒  for the conversion from English Natural Gas (NG) to Liquid Technical Data......... 2 Propane Gas (LPG) High Altitude ........2 ⇒  for the conversion from Conversion Procedure ....
  • Page 2: Technical Data

    For high altitude installations in Canada, the conversion shall be carried out by a manufacturer’s authorized representative, in accordance with the requirements of the manufacturer, provincial or territorial authorities having jurisdiction and in accordance with the requirements of CAN/CGA-B149.1 or CAN/CGA-B149 installation codes. Rinnai Corporation RHFE-263FAⅡ Conversion Manual...
  • Page 3: Conversion Procedure

    6. Confirm that the electrode and leads are installed. 3. Remove the burner screw from the burner 7. Complete the procedure, Adjust Gas Pressure assembly. Settings. Flame view port Manifold screw locations Injectors Electrode and leads Burner screw Primary Secondary damper damper tab Rinnai Corporasion RHFE-263FAⅡ Conversion Manual...
  • Page 4 9. The LED will display the temperature scale. Use the ▲ and ▼ buttons to select the Fahrenheit or Celsius scale. display 10.Press the SW1 switch to enter the temperature Set Temp scale into memory. Room Temp Temp Control Rinnai Corporation RHFE-263FAⅡ Conversion Manual...
  • Page 5 The LED display will display “78”. If the LED shows any thing other Yellow flames or than “78” call Rinnai Technical Support at 1-800- orange color 621-9419 for assistance. 19. Press the ON/OFF button again. The LED...
  • Page 6: Francais

    évitée peut entraîner des blessures graves voire mortelles. Indication d’une situation potentiellement dangereuse, qui si elle n’est pas évitée ATTENTION peut entraîner des blessures légères ou moyennes. On peur également l’utiliser pour signaler des pratiques non sûres. Ⅱ Rinnai Société RHFE-263FA Manuel de conversion...
  • Page 7: Données Techniques

    Pour des installations d'altitude élevée au Canada, la conversion doit être effectuée en suivant les conditions requises par les autorités des provinces ayant jurisdiction et conformément aux exigences 1 et 2 du Code d’Installation CAN1-B149. Ⅱ Rinnai Société RHFE-263FA Manuel de conversion...
  • Page 8: Procédure De Conversion

    Pression de Gaz. secondaires avec les amortisseurs pour le type de gaz être utilisés. (Tirer l'amortisseur Flamber l'hublot Les emplacements divers de vis Injecteurs L'électrode et mène Vis de brûleur Amortisseur primaire L'étiquette secondaire d'amortisseur Ⅱ Rinnai Société RHFE-263FA Manuel de conversion...
  • Page 9 Set Temp ▲ et ▼ Les boutons pour choisir l'échelle Fahrenheit ou Celsius. Room Temp 10. Appuyer le SW1 commutateur pour entrer l'échelle de La temp é rature Temp température dans la mémoire. Commande Control Ⅱ Rinnai Société RHFE-263FA Manuel de conversion...
  • Page 10 Flamber la Tringle pression de feu dans la mémoire. L'exposition MENEE affichera « 78 ». Si les spectacles MENES n'importe quelle chose autrement que « 78 » Rinnai d'appel Soutien Technique à 1-800- Le jaune flambe 621-9419 pour l'assistance. ou la couleur orange 19.
  • Page 11: Parts List

    Visual Reference (Nom de la Pièce) (Numero de Pièce) (Gaz) (Quantité) (Référence visuelle) Injector AU129-210-0.90 (Injecteur) Primary Damper 308F-209-7 (Registre Primaire) Secondary Damper 308F-218-3 (Φ2.5×10) (Registre Secondaire) Conversion Plate CP-72317-12 (Plaque de conversion) Ⅱ Rinnai Société RHFE-263FA Manuel de conversion...
  • Page 12 1 0 3 International Drive, Peachtree City, Georgia 3 0 2 6 9 Phone:1-8 0 0-6 2 1-9 4 1 9 Fax:1-8 8 8-4 7 4-6 6 2 4 308F-2073 (00) Printed in Japan  2006.10...