U-Line U-CLR1215W-40B User Manual & Service Manual page 47

Hide thumbs Also See for U-CLR1215W-40B:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
15. CLEAR ERROR LOG
To clear errors, press and hold
when CLR is flashing.
16. THERMISTOR — 1 DIFFERENTIAL
This number should not be adjusted.
17. Does not apply to this model.
18. Does not apply to this model.
19. INDIVIDUAL COMPONENT TOGGLE
Display #
Relay/Output
0
2
Relay 2
3
Relay 3
4
Relay 4
5
Relay 5
6
Relay 6
7
Relay 7
8
DC Output 1
9
DC Output 2
10
DC Output 3
11
DC Output 4
12
DC Output 5
SEE RELAY/OUTPUT CHART
20. MODEL NUMBER INDICATOR
Displays the two-digit model number of the
specific unit. See model list table.
21. LIGHT ALL LED SEGMENTS
This will illuminate all the LEDs on the display to
ensure they work properly.
22. Does not apply to this model.
23. VIEW COMPRESSOR RUNTIME
This will show the number of minutes the
compressor has run in the prior cycle (or
current cycle if the compressor was running
when service mode was entered).
24. ACTIVATE DEFROST/HARVEST
Turns on the hot gas bypass valve allowing hot
gas to circulate through the evaporator causing
frost to melt.
25. RESTORE FACTORY DEFAULTS
Will restore all adjustable functions to their
factory settings.
(5 seconds)
Exit
26. SOFTWARE VERSION — MAIN BOARD
Displays software version of the main control
board.
27. SOFTWARE VERSION —
Displays software version of the user interface.
28. LOG IN PERIOD
Factory use only - do not adjust.
29. FACTORY TEST MODE
Should be 0.
0. EXIT SERVICE MODE
47