Hide thumbs Also See for ASH-13AIA1 PT:

Advertisement

Quick Links

USER'S MANUAL
ARCTIC SERIES
outdoor unit
ASH-13AIA1 PT, ASH-18AIA1 PT

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair ASH-13AIA1 PT

  • Page 1 USER'S MANUAL ARCTIC SERIES outdoor unit ASH-13AIA1 PT, ASH-18AIA1 PT...
  • Page 2 „Original instruction“...
  • Page 3: Table Of Contents

    Content Operation Notices Precautions......................1 Parts name ......................6 Installation Notice Installation dimension diagram ................7 Tools for installation ....................8 Selection of installation location ................8 Requirements for electric connection ..............9 Installation Installation of outdoor unit ................... 10 Vacuum pumping ....................
  • Page 4: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 6 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 7 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 8 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 9: Parts Name

    Parts name Outdoor Unit air inlet Connection wire air outlet NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 10: Installation Dimension Diagram

    Installation dimension diagram Drainage pipe...
  • Page 11: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 12: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 13: Installation Of Outdoor Unit

    Installation of outdoor unit Step one: fix the support of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: ●...
  • Page 14 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- 3. Pretightening the union nut with dle of outdoor unit and then remove hand. the handle. pipe joint screw union nut handle 2.
  • Page 15 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: ● After tighten the screw, pull the power cord slightly to check if it is firm. ●...
  • Page 16: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas liquid valve piezometer valve and the nut of refri- gas valve gerant charging vent. refrigerant charging 2. Connect the charging hose valve cap vent of piezometer to the refri- gerant charging vent of gas nut of refrigerant...
  • Page 17: Check After Installation

    Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling Have you done the refrigerant leakage test? (heating) capacity.
  • Page 18: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe and max. high difference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- capacity...
  • Page 19 Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m) Φ6 Φ9.52 or Φ12 Φ6 or Φ9.52 Φ16 or Φ19 Φ12 Φ19 or Φ22.2 Φ16...
  • Page 20: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ● Confirm the pipe length according to ● Expand the port with expander. the distance of indoor unit and hard outdoor unit.
  • Page 21  ...
  • Page 22 In case of quality problem or other please contact your local supplier or authorized service center. Emergency number: 112 PRODUCER Producer: SINCLAIR CORPORATION Ltd., 1-4 Argyll St., London W1F 7LD, UK, www.sinclair-eu.com This product was manufactured in China (Made in China). REPRESENTATIVE, TECHNICAL SUPPORT NEPA spol.

This manual is also suitable for:

Arctic seriesAsh-18aia1 pt

Table of Contents