Technical Data - Dometic ACC3100D Operating Manual

Roof top ventilation system
Hide thumbs Also See for ACC3100D:
Table of Contents

Advertisement

Available languages

Available languages

EN

13 Technical data

Input voltage
Maximum power input
Maximum power consumption
Minimum power consumption
Operating temperature range
Protection class
External fuse
Ceiling vent opening
Dimension roof top unit (W x L x H)
Dimension air distribution unit (W x L x H)
Roof thickness
Outside noise level
Inside noise level
Inside noise level (sleep mode)
Ventilation
Heat recovery efficiency
Weight
Features
Certifications
Input voltage
Input power
16
ACC3100DWH(A)
7.6 W
0.18 kWh/24h
15.2 Ah
–   20 °C (–   4 °F) ... 70 °C (158 °F)
542.6 × 553 × 127 mm
517.6 × 517.6 × 46 mm
7 kg
Upgradable with:
• LED Light Strip
• Air Purification Module
• Performance Booster
• Solar Panel
ACC3100D LED Light
ACC3100DWHWLD(A)
12 V
16.5 W
0.40 kWh/24h
33 Ah
0.06 kWh/24h
4.9 Ah/24 h
IPX4
3 A
150 cm²
23 ... 60 mm
43 dB(A)
52 dB(A)
35 dB(A)
30 ... 50 m³/h
72 ... 87 %
7.14 kg
Provided with:
• LED Light Strip
• Air Purification Module
• Installation kit
Upgradable with:
• Performance Booster
• Solar Panel
12 V
8.6 W
 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acc31009620005072

Table of Contents