SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
CONTROL FUNCTION GUIDE
FUNCTION
ON/OFF
Adjust ice thickness
Sabbath Mode
Silent Mode (ice
production suspended for
3 hours)
Clean Mode
VIEWING BIN THERMISTOR SET POINT
To view the set point temperature at which the bin
thermistor will stop ice production, push and release the
up and down arrow icons. Adjustments to this can be
made in the service mode.
SILENT MODE
In some cases it may be requested for the unit to be shut
down temporarily - during meetings for example. To do
this, hold the
and
"beep" once and show 3H on the display. This mode can
be canceled by pressing and releasing
automatically be changed back to ON after three hours.
SHOWROOM MODE
This mode is designed to show units in a display environ-
ment. When in this mode the only functions will be the
control and cabinet lights. The compressor, fans, etc. will
not operate. To enter/exit this mode hold the light key
and the power key for 5 seconds. The display will flash
once and beep and the degree symbol will begin to flash.
When the degree symbol is flashing the unit will allow the
use of the control for demonstrations. The unit can be left
in this mode indefinitely.
SERVICE MODE
This mode has options available for service diagnostics.
To enter the mode hold the hidden key for 10 seconds.
The display will show "0." When in this mode use the up
and down arrows to select the desired option. The LIGHT
COMMAND
Press
and release
See "Ice" section
See "Sabbath Mode" section
Hold
and
See "Cleaning" section
for three seconds. The unit will
. The mode will
DISPLAY/OPTIONS
Unit will immediately turn ON or OFF.
Display will show "3H".
key is the ENTER key and will initiate the function. If
changing a setting, you must press the LIGHT key again
to retain the changed setting. To exit the service mode
scroll to option "0" and press the LIGHT key. After five
minutes of not touching any keys the mode will also exit
automatically.