Cisco Nexus 9332D-H2R NX-OS Hardware Installation Manual

Table of Contents

Advertisement

Quick Links

Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation
Guide
First Published: 2023-08-18
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9332D-H2R NX-OS

  • Page 1 Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide First Published: 2023-08-18 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Any products and features described herein as in development or available at a future date remain in varying stages of development and will be offered on a when-and if-available basis. Any such product or feature roadmaps are subject to change at the sole discretion of Cisco and Cisco will have no liability for delay in the delivery or failure to deliver any products or feature roadmap items that may be set forth in this document.
  • Page 3: Table Of Contents

    Installing the Switch Using the NXK-ACC-KIT-1RU Rack-Mount Kit Grounding the Chassis Starting the Switch C H A P T E R 4 Connecting the Switch to the Network Overview of Network Connections Connecting a Console to the Switch Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 4 Switch and Module Weights and Quantities Transceiver and Cable Specifications Switch Power Input Requirements Power Specifications 2000-W AC Power Supply Specifications 2000-W HVAC/HVDC Power Supply Specifications 2000-W DC Power Supply Specifications Power Cable Specifications Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 7: Overview

    Overview • Overview , on page 1 Overview The Cisco Nexus 9332D-H2R switch (N9K-C9332D-H2R) is a 1-rack unit (RU), fixed-port switch designed for deployment in data centers. This switch includes the following ports: • 400-Gigabit QSFP-DD ports (32) • 10-Gigabit SFP+ ports (2) •...
  • Page 8 Fan modules (6) with slots numbered from 1 (left) to 6 (right) power supplies shown) with slots numbered 1 (left) and 2 (right) The following figure shows the side of the chassis. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 9 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 10 Overview Overview Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 11: Preparing The Site

    Altitude Requirements Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 12: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 13: Shock And Vibration Requirements

    Rack and Cabinet Requirements You can install the following types of racks or cabinets for your switch: • Standard perforated cabinets • Solid-walled cabinets with a roof fan tray (bottom-to-top cooling) Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 14 Statement 1048 Rack Stabilization The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before installation or servicing. Failure to stabilize the rack can cause bodily injury. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 15: Installing The Chassis

    Starting the Switch, on page 19 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
  • Page 16 Statement 1091 Installation by an Instructed Person Only an instructed person or skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of an instructed or skilled person. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 17 This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 18: Installation Options With Rack-Mount Kits

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 19: Airflow Considerations

    To prevent loss of input power, ensure the total maximum loads on the circuits supplying power to the switch are within the current ratings for the wiring and breakers. Note For AC input application, please refer to the statement below: Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 20: Unpacking And Inspecting The Switch

    Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: • Invoice number of shipper (see packing slip) • Model and serial number of the damaged unit • Description of damage Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 21: Installing The Switch Using The Nxk-Acc-Kit-1Ru Rack-Mount Kit

    The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 22 (see the following figure). Tighten 12-24 screws to 30 in-lb (3.39 N·m) of torque and tighten 10-32 screws to 20 in-lb (2.26 N·m) of torque. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 23 Holding the chassis level, insert screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of six screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 24: Grounding The Chassis

    This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 25: Starting The Switch

    If you need n+n redundancy, you must connect each power supply in a switch to a different power source. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 26 4. Place the power cable positive-wire terminal ring on the positive terminal for the power source and secure them with a terminal nut. 5. Place the power cable ground-wire terminal ring on the ground terminal for the power source and secure them with a terminal nut. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 27 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 28 Installing the Chassis Starting the Switch Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 29: Connecting The Switch To The Network

    When running cables in overhead or subfloor cable trays, we strongly recommend that you locate power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 30: Connecting A Console To The Switch

    • Network cabling is routed to the location of the installed switch. Step 1 Configure the console device to match the following default port characteristics: • 9600 baud • 8 data bits • 1 stop bit • No parity Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 31: Creating The Initial Switch Configuration

    To connect the switch to the network, you can use the default choices for each configuration except the IP address, which you must provide. You can perform the other configurations later as described in the Cisco Nexus 9000 Series NX-OS Fundamentals Configuration Guide.
  • Page 32 The software asks if you need to save the configuration. Step 8 Enter yes to save the configuration. What to do next You can now set up the management interface for each supervisor module on the switch. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 33: Setting Up The Management Interface

    When removing transceivers from the switch, it is best to remove the optical cable first and then remove the transceiver. To determine which transceivers, adapters, and cables are supported by this switch, see the Cisco Transceiver Modules Compatibility Information document. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 34 Connecting the Switch to the Network Connecting Interface Ports to Other Devices Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 35: Replacing Components

    On the fan module that you are removing, press the two sides of the fan module handle together, and pull on the handles enough to unseat it from its connectors. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 36: Installing A Fan Module

    Pull the power cord out from the power receptacle on the power supply to be removed and verify that the LED turns off. The LED might be on and amber colored to indicate that the input power has been disconnected. Note Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 37: Removing An Hvac/Hvdc Power Supply

    Turn off the circuit breaker for the power feed to the power supply that you are replacing. Be sure that the LEDs turn off on the power supply that you are removing. Step 2 Remove the power cable from the power supply by doing the following: Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 38: Installing An Ac Power Supply

    Make sure that the other end of the power cable is attached to the appropriate power source for the power supply. Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper Note cable to connect the switch to your outlet receptacle. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 39: Installing An Hvac/Hvdc Power Supply

    Verify that the power supply is operational by making sure that the power supply LED is green. Installing a DC Power Supply You can replace one power supply while the other one provides power to the switch. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 40 Turn on the circuit breaker for the DC power source connected to the power supply. Step 4 Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 41: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 42: Requirements Specific To Standard Open Racks

    To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 43: System Specifications

    0 to 13,123 feet (0 to 4,000 meters) Switch Dimensions Switch Width Depth Height Cisco Nexus 9332D-H2R 17.3 inches (43.9 cm) 29.3 in (74.5 cm) 1.72 inches (4.4 cm) (1 RU) Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 44: Switch And Module Weights And Quantities

    To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed in the following table. Switch Typical Power Consumption (AC or DC) Maximum Power Heat Dissipa Consumption (AC or Requirement Cisco Nexus 9332D-H2R BTUs per ho (TBD) Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 45: Power Specifications

    Efficiency 90% or greater (20 to 100% load) Redundancy Modes Combined, n+1, and n+n RoHS Compliance Hot Swappable 2000-W DC Power Supply Specifications These specifications apply to the NXA-PDC-2KW power supplies. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 46: Power Cable Specifications

    Power Cables for NXA-PAC-2KW Power Supplies Cable Description Illustration CAB-TA-NA North America AC Type A Power Cable CAB-TA-UK United Kingdom AC Type A Power Cable CAB-TA-250V-JP Japan 250V AC Type A Power Cable Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 47: Hvac/Hvdc Power Cables Supported By Aci-Mode And Nx-Os Mode Switches

    Israel AC Type A Power Cable HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches Part Number Cord Set Description Photo CAB-HVAC-SD-0.6M HVAC 2-foot (0.6 m) cable with Saf-D-Grid and SD connectors 277V AC Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 48 (+200/-200 V DC) NO-POWER-CORD All except Argentina, Not applicable Brazil, and Japan No power cord included with switch Table 1: HVAC/HVDC Power Cables Callout Table Connect this end to the power supply unit. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 49: Dc Power Cable Specifications

    Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. Safety • CAN/CSA-C22.2 No. 60950-1 Second Edition • NRTL 60950-1 Second Edition • IEC 62368-1 • EN 62368-1 • AS/NZS 62368-1 • GB4943 Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 50 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 51: Appendix Cleds

    Amber Port admin state is 'Disabled, or the SFP is absent, or both. Port admin state is 'Enabled' and SFP is present, but interface is not connected. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 52: Fan Module Leds

    • High temperature • High power • Slow power supply fan • Low voltage • Power supply is installed in the chassis but was disconnected from the power source. Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 53 Power supply is installed without a connection to a power source. (10 seconds) then amber Amber Power supply failure—possibly one of the following conditions: • Over voltage • Over current • Over temperature • Power supply fan failure Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 54 LEDs LEDs Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 55: Additional Kits

    Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...
  • Page 56 Additional Kits Additional Kits Cisco Nexus 9332D-H2R NX-OS Mode Switch Hardware Installation Guide...

Table of Contents