Bath And Shower Rooms; Ventilation - Baxi 7682194 Installation And Service Manual

High efficiency wall hung condensing gas boiler
Table of Contents

Advertisement

Fig.12
Bathroom 1 and 2
B
D
C
A
0.6m
D
D
B
C
A
0.6m
7679306 - 1 - 10082017
5.3.2
A
B
C
D
E
F
Bathroom 1 and 2 ( in GB only) shows zone dimensions for a bathtub. For
other examples refer to the Current IEE Wiring Regulations). Reference
must be made to the relevant requirements.
In GB this is the current IEE. Wiring Regulations and Building Regulations.
In IE reference should be made to the current edition of IS 813 "Domestic
E
Gas Installations" and the current ETCI rules.
F
2.25m
PN-0000400
5.3.3
Where the appliance is installed in a cupboard or compartment, no air
vents are required. BS 5440: Part 2 refers to room sealed appliances in­
stalled in compartments. The appliance will run sufficiently cool without

ventilation.

Bath and shower rooms

Zone 0
Zone 1
Zone 2
Window recess Zone 2
Ceiling
Outside zones
Important
Where an optional plug-in integral timer, RF receiver or thermostat
is NOT FITTED the boiler has a protection rating of IPX5D and if
installed in a room containing a bath or shower can be within Zone
2 (but not 0 or 1).
Important
A boiler fitted with an optional plug-in integral timer, RF receiver or
thermostat CANNOT be fitted in any zone.
Ventilation
5 Before installation
29