About the refrigerant
• This product contains fl uorinated greenhouse gases.
• Do not vent gases to the atmosphere.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open fl ames, an
operating gas appliance or an operating electric heater).
• Do not pierce or burn refrigerant cycle parts.
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
• Be aware that refrigerants may not contain an odour.
• The refrigerant inside the unit is fl ammable. If the refrigerant
leaks in the room and comes in contact with fi re from a burner,
a heater, or a cooker, it may result in fi re or the formation of a
harmful gas.
• Turn off any combustible heating devices, ventilate the room,
and contact the dealer from which you purchased the unit.
• Do not use the unit until a service person confi rms that the
portion from which the refrigerant leaked is repaired.
• When installing, relocating, or servicing the air conditioner, use
only the specifi ed refrigerant (R32) to charge the refrigerant
lines. Do not mix it with any other refrigerant and do not allow
air to remain in the lines.
• Pipe-work shall be protected from physical damage.
• Compliance with national gas regulations shall be observed.
9-EN
– 5 –
Selection of installation location
• If you install the unit in a small room, take appropriate measures
to prevent the refrigerant from exceeding the limit concentration
even if it leaks. Consult the dealer from whom you purchased
the air conditioner when you implement the measures.
Accumulation of highly concentrated refrigerant may cause an
oxygen defi ciency accident.
• Do not install the air conditioner in a location that may be
subject to a risk of expire to a combustible gas. If a combustible
gas leaks and becomes concentrated around the unit, a fi re
may occur.
• When transporting the air conditioner, wear shoes with
additional protective toe caps.
• When transporting the air conditioner, do not take hold of the
bands around the packing carton. You may injure yourself if the
bands should break.
• Do not place any combustion appliance in a place where it is
directly exposed to the wind of air conditioner, otherwise it may
cause imperfect combustion.
• Do not install the air conditioner in a poorly ventilated space that
is smaller than the minimum fl oor area (A
This applies to:
• Indoor units
• Outdoor units installed
(example: winter garden, garage, machinery room, etc)
Refer to "15 Appendix - [2] Minimum fl oor area: A
determine the minimum fl oor area.
).
min
(m
2
)" to
min
10-EN