Download Print this page
U-Line U-29RW-00A User Manual & Service Manual
U-Line U-29RW-00A User Manual & Service Manual

U-Line U-29RW-00A User Manual & Service Manual

Hide thumbs Also See for U-29RW-00A:

Advertisement

Quick Links

USER GUIDE & SERVICE MANUAL
Model: U-29RW-00A

Advertisement

loading

Summary of Contents for U-Line U-29RW-00A

  • Page 1 USER GUIDE & SERVICE MANUAL Model: U-29RW-00A...
  • Page 2 USER GUIDE & SERVICE MANUAL Click on any section below to jump directly there Table of Contents Intro Parts Ordering Replacement Parts Safety R600a Specifications Safety and Warning System Diagnosis Guide Disposal And Recycling Compressor Specifications Troubleshooting Extended Installation Defrost Environmental Requirements Warranty Electrical...
  • Page 3 U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4 USER GUIDE Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5 USER GUIDE Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:...
  • Page 6 USER GUIDE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
  • Page 7 USER GUIDE Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8 Cutout Dimensions PREPARE SITE 20 ⁄ ” Cutout & Product Dimensions Your U-Line product has been designed for either free- (529mm) standing or built-in installation. When built-in, your unit PREPARE SITE does not require additional air space for top, sides, or rear.
  • Page 9 USER GUIDE Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Tighten screws fully. Cutout width for a side-by-side installation is the cutout 4.
  • Page 10 USER GUIDE General Installation INSTALL DOOR HANDLE In the literature package inside the unit, there is a handle LEVELING INFORMATION that was specially designed for this door. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. On the upper side of the door, opposite to the hinges, there are 2 screws.
  • Page 11 USER GUIDE Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. WARNING DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged. Removing the grille 1.
  • Page 12 USER GUIDE Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
  • Page 13 USER GUIDE Door Adjustments Remove arrow clips: With a puddy knife or other flat tool, gently pry each DOOR ALIGNMENT AND ADJUSTMENT arrow clip from hinge mounting holes. Align and adjust the door if it is not level or is not sealing Set aside arrow clips to be reused on the opposite properly.
  • Page 14 USER GUIDE Remove bottom hinge: Remove bottom hinge from cabinet using a 1/4” socket. Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind one or both screws on either side. Install bottom hinge: Install two or three screws, depending on model.
  • Page 15 USER GUIDE First Use All U-Line controls are preset at the factory. Initial startup requires no adjustments. NOTICE U-Line recommends allowing the unit to run overnight before loading with product. U-Line recommends discarding the ice produced during the first two or three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
  • Page 16 ⁄ ” ⁄ ” (66 mm) (64mm) When determining capacities U-Line uses typical 12 oz. cans, 12 oz. bottles, 750 mL white wine and red wine bottles shown below. ⁄ ” ⁄ ”...
  • Page 17 USER GUIDE Interior Shelves NOTICE Make sure the shelves are inserted fully into the REMOVING AND INSTALLING INTERIOR unit. SHELVES The edge strip toward the rear prevents cans and bottles from freezing against the cold evaporator. For models equipped with glass shelves having recessed shelf supports, remove the shelves as follows: 1.
  • Page 18 USER GUIDE Cleaning If any surface discoloring or rusting appears, clean it ® ® quickly with Bon-Ami or Barkeepers Friend Cleanser EXTERIOR CLEANING and a nonabrasive cloth. Always clean with the grain. ® Always finish with Claire Stainless Steel Polish and Vinyl Clad (Black or White) Cleaner or comparable product to prevent further Clean surfaces with a mild detergent and warm water...
  • Page 19 USER GUIDE High ambient temperature and excessive humidity can also produce frost. CAUTION DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost.
  • Page 20 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary.
  • Page 21 If the unit will be exposed to temperatures of 40 F (5 C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. CAUTION Damage caused by freezing temperatures is not covered by the warranty. Extended Non-Use...
  • Page 22 BEFORE CALLING FOR SERVICE • Condenser Fan: Air moving through a condenser may be heard. If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the • Automatic Defrost Drain Pan: Water may be heard function of the control.
  • Page 23 USER GUIDE CHECKING PRODUCT TEMPERATURE Causes which affect the internal temperatures of the cabinet include: • Temperature setting. • Ambient temperature where installed. • Installation in direct sunlight or near a heat source. • The number of door openings and the time the door is open.
  • Page 24 USER GUIDE Wire Diagram Wire Diagram...
  • Page 25 The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 26 Claims must be submitted online at • Final billing - Remodel www.U‑LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 27 USER GUIDE Parts 22 23 U-29RW-00A Item Description U-Line P/N BACK PANEL 80-54505-00 BOTTLE RETAINER , LONG 80-54530-00 BOTTLE RETAINER , SHORT 80-54533-00 COMPRESSOR ELECTRICALS ONLY 80-54149-00 COMPRESSOR W/ELECTRICALS 80-54150-00 CONDENSER ASSEMBLY 80-54521-00 CONDENSER FAN W/SCREWS 80-54014-00 CONTROL ASSEMBLY 80-54192-00...
  • Page 28 Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 29 Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
  • Page 30 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
  • Page 31 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
  • Page 32 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
  • Page 33 USER GUIDE System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold Slightly warm Hot to warm Cool...
  • Page 34 USER GUIDE USER GUIDE u-line.com Compressor Specifications OVERLOAD PROTECTOR STARTING RELAY DANGER Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing RELAY COVER CAPACITOR this unit. EMX20CLC Disconnect the power source.
  • Page 35 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Troubleshooting - Extended NORMAL OPERATING SOUNDS • Evaporator: Refrigerant flowing through an evaporator All models incorporate rigid foam insulated cabinets to may sound like boiling liquid.
  • Page 36 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE THEORY OF OPERATION Cooling process Refrigerant is pumped from the compressor to the condenser as a high pressure, high temperature vapor. COMPRESSOR CONDENSER...
  • Page 37 USER GUIDE Defrost These units are automatic (cycle) defrost unit will defrost itself when the control/sensor is satisfied of internal temperatures. Defrost mode ends when control/sensor asks for cooling. Defrost 1...
  • Page 38 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.