To Use The Dry Program (Without Cool/Heat Changeover Remote Control Switch); To Use The Dry Program (With Cool/Heat Changeover Remote Control Switch); Adjusting The Air Flow Direction; About The Air Flow Flap - Daikin RXYSQ5T8VB Installation And Operation Manual

System air conditioner
Table of Contents

Advertisement

12.3.2
To use the dry program (WITHOUT cool/
heat changeover remote control switch)
To start
1 Press the operation mode selector button on the user interface
several times and select
2 Press the ON/OFF button of the user interface.
Result: The operation lamp lights up and the system starts
operating.
3 Press the air flow direction adjust button (only for double-flow,
multi-flow, corner, ceiling-suspended and wall-mounted). Refer
to
"12.4 Adjusting the air flow direction" on page 29
To stop
4 Press the ON/OFF button on the user interface once again.
Result: The operation lamp goes out and the system stops
operating.
NOTICE
Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.
12.3.3
To use the dry program (WITH cool/heat
changeover remote control switch)
To start
1 Select cooling operation mode with the cool/heat changeover
remote control switch.
1
1
2 Press the operation mode selector button on the user interface
several times and select
3 Press the ON/OFF button of the user interface.
Result: The operation lamp lights up and the system starts
operating.
4 Press the air flow direction adjust button (only for double-flow,
multi-flow, corner, ceiling-suspended and wall-mounted). Refer
to
"12.4 Adjusting the air flow direction" on page 29
To stop
5 Press the ON/OFF button on the user interface once again.
Result: The operation lamp goes out and the system stops
operating.
NOTICE
Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.
12.4

Adjusting the air flow direction

Refer to the operation manual of the user interface.
12.4.1

About the air flow flap

Double flow+multi-flow units
Corner units
RXYSQ4~6T8V/YB
VRV IV-S system air conditioner
4P482275-1 – 2017.04
(program dry operation).
for details.
(program dry operation).
for details.
Ceiling suspended units
Wall-mounted units
For the following conditions, a micro computer controls the air flow
direction which may be different from the display.
Cooling
▪ When the room temperature is
lower
than
the
set
temperature.
▪ When operating continuously at horizontal air flow direction.
▪ When continuous operation with downward air flow is performed
at the time of cooling with a ceiling-suspended or a wall-mounted
unit, the micro computer may control the flow direction, and then
the user interface indication will also change.
The air flow direction can be adjusted in one of the following ways:
▪ The air flow flap itself adjusts its position.
▪ The air flow direction can be fixed by the user.
▪ Automatic
and desired position
WARNING
Never touch the air outlet or the horizontal blades while the
swing flap is in operation. Fingers may become caught or
the unit may break down.
NOTICE
▪ The movable limit of the flap is changeable. Contact
your dealer for details. (only for double-flow, multi-flow,
corner, ceiling-suspended and wall-mounted).
▪ Avoid operating in the horizontal direction
cause dew or dust to settle on the ceiling or flap.
12.5

Setting the master user interface

12.5.1

About setting the master user interface

a
b
c
c
f
d
d
a
VRV IV-S Heat pump outdoor unit
b
Refrigerant piping
c
VRV direct expansion (DX) indoor unit
d
User interface (dedicated depending on indoor unit type)
e
BP box (required to connect Residential Air (RA) or Sky Air
(SA) direct expansion (DX) indoor units)
f
Residential Air (RA) direct expansion (DX) indoor units
g
User interface (wireless, dedicated depending on indoor
unit type)
When the system is installed as shown in the figure above, it is
necessary to designate one of the user interfaces as the master user
interface.
The displays of slave user interfaces show
under centralised control) and slave user interfaces automatically
follow the operation mode directed by the master user interface.
12 Operation
Heating
▪ When starting operation.
▪ When the room temperature is
higher
than
the
temperature.
▪ At defrost operation.
.
. It may
e
e
f
g
g
(change-over
Installation and operation manual
set
29

Advertisement

Table of Contents
loading

Table of Contents