8.0
INSTALLATION
8.7
Fitting the Flue (Cont)
Waste
Y
5. Mark dimension 'Y' on the flue as shown (Fig. 26).
Carefully cut the waste material from the flue,
ensuring that the ducts are square and free from
burrs.
6. The inner flue duct support bracket may be in the
Flue
waste portion of the flue. In this case retrieve the
Fig. 26
bracket before discarding the waste.
7. Take the inner flue support bracket (if not already
fitted) and engage it over the flue duct. This will
centralise the flue and air ducts, and ease assembly
(Fig. 27).
Inner Flue Support Bracket
8. Insert the flue through the hole in the wall. Fit the
elbow to the boiler adaptor, ensuring that it is
pushed fully in.
9. Draw the flue back through the wall and engage it
in the elbow. It may be necessary to use soap
solution or similar to ease assembly of the elbow
adaptor and flue (Fig. 28).
Fig. 27
10. Make good between the wall and air duct
outside the building.
11. Fit the flue trim if required, and if necessary fit a
terminal guard (see Section 7.9 & 7.10).
VERTICAL FLUE
1. Only a flue approved with the Main Combi 24 HE
can be used.
Flue Elbow
Flue Trim
Fig. 28