TABLE 22: DR240 BLOWER PERFORMANCE - 20 TON STANDARD DRIVE (GAS HEAT) DOWNFLOW
ESP CFM RPM KW BHP CFM RPM KW BHP CFM RPM KW BHP CFM RPM KW BHP CFM RPM KW BHP CFM RPM KW BHP
0.4 9161 1010 6.31 7.69 8666
0.6 8702 1011 6.08 7.42 8228
0.8 8291 1012 5.63 6.87 7804
1.0 7901 1013 5.32 6.50 7375
1.2 7468 1014 5.02 6.13 6941
1.4 7033 1015 4.66 5.69 6458
1.6 6247 1017 4.15 4.98 5945
1.8 5854 1018 3.89 4.67 5430
2.0 5461 1020 3.63 4.36
1 turn
7.5 HP motor
10000
1 Turn
9000
2 Turns
3 Turns
8000
4 Turns
5 Turns
6 Turns
7000
6000
5000
4000
3000
0.2
0.4
Johnson Controls Unitary Products
Available External Static Pressure - IWG
978 5.74 7.01 8277
947 5.17 6.31 7918
979 5.38 6.56 7935
948 4.86 5.93 7471
980 5.04 6.16 7401
949 4.49 5.48 7019
981 4.80 5.86 6992
950 4.13 4.95 6547
982 4.37 5.34 6510
951 3.90 4.68 6045
984 4.08 4.89 5973
953 3.36 4.03 5489
985 3.73 4.48 5439
955 3.09 3.71 4933
987 3.39 4.06 4871
956 2.82 3.39
-
-
-
-
-
-
2 turns
3 turns
5 HP motor
20-Ton Standard Drive, Gas Heat, Bottom Connection
0.6
0.8
External Static ("WC)
915 4.56 5.56 7510
917 4.28 5.22 7027
918 4.05 4.86 6549
919 3.69 4.43 6043
920 3.46 4.15 5472
922 3.08 3.70 4902
923 2.71 3.25 4070
-
-
-
-
-
-
-
-
4 turns
VP68 x BK110
1.0
1.2
1.4
284811-YIM-C-1008
883 4.11 4.93 7146
884 3.73 4.47 6650
885 3.43 4.12 6137
886 3.21 3.86 5591
887 2.91 3.50 5001
888 2.62 3.14 4352
889 2.24 2.69 3465
-
-
-
-
-
-
-
-
-
-
-
-
5 turns
1.6
1.8
2.0
851 3.57 4.28
852 3.41 4.09
853 3.11 3.73
854 2.73 3.28
855 2.58 3.10
856 2.11 2.54
857 1.88 2.26
-
-
-
-
-
-
6 turns