Clean & Clear
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SECTION I.
FILTER INSTALLATION ................................................................................... 1
SECTION II.
FILTER OPERATION AND CLEANING ........................................................... 3
SECTION III.
TROUBLE SHOOTING ....................................................................................... 7
SECTION IV.
TECHNICAL DATA ........................................................................................... 9
Before installing this product, read and follow all warning notices and instructions accompanying this filter.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call
(800) 831-7133 for additional free copies of this manual.
Attention Installer.
This manual contains important information about the installation, operation and safe use
of this product. This information should be given to the owner/operator of this equipment.
SECTION I.

FILTER INSTALLATION

A. GENERAL INFORMATION
1. The filter should be mounted on a level concrete slab. Position the filter so that instructions,
warnings and the pressure gauge are visible to the operator. It also should be positioned so
that the piping connections, control valve and drain port are convenient and accessible for
servicing and winterizing.
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330• (800) 831-7133 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
Visit www.pentairpool.com or www.staritepool.com
Rev. M 4-18-12
®
Plus Cartridge Filters Owner's Manual
SAVE THESE INSTRUCTIONS
Table of Contents
WARNING
Important Notice
1
P/N 178558

Advertisement

loading

Summary of Contents for Pentair Pool Products Clean & Clear Plus 240

  • Page 1: Filter Installation

    ® Clean & Clear Plus Cartridge Filters Owner's Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. FILTER INSTALLATION ................... 1 SECTION II. FILTER OPERATION AND CLEANING ............3 SECTION III. TROUBLE SHOOTING ..................7 SECTION IV.
  • Page 2 2. Be certain to install electrical controls (e.g., on/off switches, timers, control systems, etc.) at least five (5) feet from the filter. This permits one to stand clear of the filter during system start up. Allow sufficient clearance around the filter to permit visual verification that the clamp is properly installed around the tank flanges, see Figure A.
  • Page 3: Filter Operation And Cleaning

    approved automatic Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system. SECTION II. FILTER OPERATION AND CLEANING WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., FILTER LID, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED.
  • Page 4 The pressure gauge is the primary indicator of how the filter is operating. Maintain your pressure gauge in good working order. WARNING Your filter is a piece of machinery, do not tamper with it, attempt to disassemble it or otherwise adjust it unless you fully understand it's operation.
  • Page 5 Begin to tighten nut using a 7/8" wrench. Then tap around the outside of the filter clamp with a mallet (or similar tool) to insure uniform loading and proper seating of the clamp. Continue tapping and tightening until the spring coils touch each other. Do not tighten beyond this point. Follow the procedures in Section C, System Restart Instructions.
  • Page 6 1. Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently started during servicing. 2. Open the filter High Flow™ manual air relief valve (and the waste drain valve or plug, if your system has one).
  • Page 7: Trouble Shooting

    E. REPLACING FILTER CARTRIDGES Filter cartridge element life will vary with pool conditions such as bather load, wind, dust, etc. You can expect an average cartridge life of 3 years under normal conditions. To replace cartridge element follow steps in Section D, Cleaning Filter, eliminating step D.7. F.
  • Page 8 C. If pressure drops on gauge, check skimmer basket and pump basket first for debris. If the baskets are clean, shut off power to pump and turn off any automatic controls. Then turn motor shaft with your fingers. If it turns freely then the pump must be disassembled and the impeller checked to see if it is clogged.
  • Page 9: Technical Data

    SECTION IV. TECHNICAL DATA A. FLOW RATES PRESSURE DROP vs FLOW FLOW (gpm) ® & r t r e t l y t i o l l l i F r e t c i t * l a . t f .
  • Page 10 ® B. CLEAN & CLEAR PLUS TANK ASSY. 8, 17 P/N 178558 Rev. M 4-18-12...
  • Page 11 ® B. CLEAN & CLEAR PLUS TANK ASSY., cont'd. Replacement Parts Item No. Part No. Description Item No.Part No. Description 190058 Gauge, pressure, ¼ in. 195610 Washer, small I.D. 98209800 High Flow™ manual air relief valve 195611 Washer, large I.D. (HFMARV) 194997 Nut, machined...
  • Page 12 1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000 This document is subject to change without notice. Trademarks and Disclaimers: Pentair Pool Products ® , Because reliability matters most ®...