6. OUTDOOR FAN CONTROL

1. Outdoor Fan Motor
The Table 7 shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table 7 : Type of Motor )
AOU9 / 12 / 15RLFF
2. Fan Speed
( Table 8 : Outdoor fan speed )
AOU9RLFF
AOU12RLFF
AOU15RLFF
Refer to Fig. 8
( Fig. 8 : Outside air temperature zone selection )
Outside air
temperature
70°F
(21°C)
54°F
(12°C)
36°F
(2°C)
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as Table 9 without relating to the compressor frequency.
( Table 9 : Outdoor fan speed after the defrost )
AOU9RLFF
AOU12RLFF
AOU15RLFF
AC Motor
Zone
Cooling
Y
1050/ 870/ 720/ 590/ 530
Z
300
F
300/ 250
G
250/ 200
1050/ 870/ 720/ 590/ 530
Y
Z
870/530/300
F
300/ 250
250/ 200
G
1050/ 870/ 720/ 530
Y
870/ 530/ 300
Z
F
300
250/ 200
G
Y zone
Z zone
F zone
G zone
1100rpm
1100rpm
1100rpm
DC Motor
1100/ 870/ 780/ 720/ 590/ 480
1100/ 870/ 780/ 720/ 590/ 480
1100/ 1000/ 780/ 720/ 590/ 480
Outside air
temperature
66°F
(19°C)
50°F
(10°C)
32°F
( 0°C)
01-06
Heating
Dry
530
530
530
(rpm)