Download Print this page

Yaesu NEDSP1061 Fitting Instructions Manual page 5

Noise reduction module

Advertisement

Replace the main unit PCB.
The NEDSP1061 screened lead fits in the cut out provided for the front antenna connector.
Replace the main unit, connections, and all screws except the front right hand screw.
Drill the holes for the lid, as per the drawing at the back of this document.
Using hot melt adhesive affix the small keyboard to the inside of the lid. Taking care to not
get adhesive on the upper surface of the lid, switch or LED.
Allow this to cure before continuing.
The NEDSP1061 can be affixed in two positions.
The preferred position is in the location of the optional filter. This provides the more
mechanically secure location. If the optional filter is (or is going to be) installed the module
can be installed along side the filter.
Solder the red (power) lead to the drain of Q1082 (TP1084).
Connect M3 ring tag (0V leads) using the right front screw.
Affix the NEDSP1061 module using the supplied self adhesive pad in the chosen location.
See the following diagram.
Keep this area clear
for speaker
Screened lead
Keyboard assembly
All manuals and user guides at all-guides.com
Alternative location
for NEDSP1061
(mount DSP up)
NEDSP1061 pre-
ferred postition
(mount DSP down)
FT-817 speaker connector
Power lead
M3 ring tag
Ensure these wires do not
foul the lid when fitted