Parameter Report - Hussmann SPECIALTY TY3-3X4.5E-R User Manual

Island merchandiser
Table of Contents

Advertisement

Parameter
Temperature (set point)
Deli (Type I)
Deli (Deli Type II)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Adjustment of temperature indication
Temperature unit (°C=0/°F=1)
Correction of the signal from S4
Correction of the signal from S3
Manual service, stop regulation, start regulation (-1, 0,
1)
Displacement of reference during night operation
Definition and weighting, if applicable, of thermostat
sensors - S4% (100%=S4, 0%=S3)
The heating function is started a number of degrees
below the thermostats cutout temperature
Activation of reference displacement r40
Value of reference displacement (activate via r39 or DI)
Alarm
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit
Low alarm limit
Alarm delay DI1
Alarm delay DI2
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Compressor
Min. ON-time
Min. OFF-time
Time delay for cutin of comp.2
Compressor relay 1 must cutin and out inversely
(NC-function)
Defrost
Defrost method (none/EL/GAS/BRINE)
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cutin of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cutin during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
Defrost Sensor (0=time, 1=S5. 2=S4)
Pump down delay
Drain delay
Max. aggregate refrigeration time between two
defrosts
Defrost on demand - S5 temperature's permitted
variation during frost build-up. On central plant choose
20 K (=off )
Delay of hot gas defrost
Fan
Fan stop at cutout compressor
Delay of fan stop
Fan stop temperature (S5)
HACCP
Actual temperature measurement for the HACCP
Last registered peak temperature
Selection of function and sensor for the HACCP
HACCP function. 1 = S4 used (maybe also S3). 2 = S5
Alarm limit for the HACCP function
Time delay for the HACCP alarm
Select signal for the HACCP function. S4% (100% = S4,
11. TY Parameter Report
TY
Code
Min
Max
---
-50.0°C
50.0°C
---
-50.0°C
50.0°C
r01
0.1 K
20.0K
r02
-49.0°C
50°C
r03
-50.0°C
49.0°C
r04
-20.0 K
20.0 K
r05
0
r09
-10.0 K
+10.0 K
r10
-10.0 K
+10.0 K
r12
-1
r13
-10.0 K
10.0 K
r15
0%
100%
r36
-15.0 K
-3.0 K
r39
OFF
r40
-50.0 K
50.0 K
A03
0 min
240 min
A04
0 min
240 min
A12
0 min
240 min
A13
-50.0°C
50.0°C
A14
-50.0°C
50.0°C
A27
0 min
240 min
A28
0 min
240 min
A36
0%
100%
c01
0 min
30 min
c02
0 min
30 min
c05
0 sec
999 sec
c30
0
OFF
d01
no
d02
0.0°C
25.0°C
d03
0 hours
240 hours
d04
0 min
180 min
d05
0 min
240 min
d06
0 min
60 min
d07
0 min
60 min
d08
-15.0°C
0.0°C
d09
0
d10
0
d16
0 min
60 min
d17
0 min
60 min
d18
0 hours
48 hours
d19
0.0 K
20.0 k
d23
0 min
60 min
F01
no
F02
0 min
30 min
F04
-50.0°C
50.0°C
h01
h10
h11
0
h12
-50.0°C
50.0°C
h13
0 min.
240 min.
h14
0%
100%
58
PGM0010A01
TANDARD CASE REV B 9/6/1 Sheetz REV B 9/21/17
Default
Actual (°C)
2.0°C
-3.3
2.0°C
-5.0
2.0 K
5.6
50.0°C
5.6
-50.0°C
-7.8
0.0 K
0.0 K
1
0
1
0.0 K
0.0 K
0.0 K
0.0 K
1
0
1
0.0 K
0.0 K
100%
100%
-15.0 K
-15.0 K
ON
OFF
OFF
0.0 K
0.0 K
30 min
30 min
60 min
60 min
90 min
60
8.0°C
5.0
-30.0°C
-9.4
30 min
30 min
30 min
30 min
100%
100%
0 min
1
0 min
2
0 sec
0 sec
1
0
0
ON
OFF
OFF
bri
EL
EL
6.0°C
11.1
8 hours
4
45 min
50
0 min
0 min
0 min
0 min
0 min
0 min
-5.0°C
-5.0°C
2
1
1
2
0
1
0 min
0 min
0 min
0 min
0 hours
4
20.0 K
1.7
0 min
0 min
yes
no
no
0 min
0 min
50.0°C
50.0°C
2
0
0
8.0°C
8.0°C
30 min.
30 min.
100%
100%
PGM0010A02
Actual (°F)
Actual (°C) Actual (°F)
26
-5.0
23
23
10
4.5
8
42
3.9
39
18
-5.0
23
0.0 K
1
0.0 K
0.0 K
1
0.0 K
100%
-15.0 K
OFF
0.0 K
30 min
60 min
60
41
5.0
41
15
-9.4
15
30 min
30 min
100%
1
2
0 sec
0
OFF
EL
52
11.1
52
4
50
0 min
0 min
0 min
-5.0°C
1
1
0 min
0 min
4
3
1.7
3
0 min
no
0 min
50.0°C
0
8.0°C
30 min.
100%