Page 2
Image shaping and other effects can be used to creative advantage, often adding a winning edge over comparable images. In this way the ArcBody can be seen as a double investment, not only by solving problems but also by providing additional creative input into image making.
Page 3
120, 220 and 70 mm perforated film types as well as Polaroid type instant films. The ArcBody serves equally well as a main camera or as an extra versatile tool. It is rugged enough to be used profession- ally on a daily basis yet compact and light enough to be included as an extra resource on all assignments.
Supplied Accessories 1 – 2 1. Lens alignment index 2. Spirit level The Hasselblad ArcBody camera and lenses are avail- 3. Film winding crank lock able in a variety of combinations and therefore the 4. Film winding crank accessories that are supplied vary accordingly. Figs.
47033 Camera inverter mount 47040 Extension tube 8 ArcBody Hasselblad ArcBody Kit - 17511 47045 Extension tube 16 ArcBody The Hasselblad ArcBody kit consists of the 47049 Extension tube 26 ArcBody Hasselblad ArcBody complete - 17015 package as listed above, plus the following: 47057 Centre filter 27045 Rodenstock Apo-Grandagon 4.5/45 mm...
Page 28
ArcBody. The cable release provides a smooth and vibration free action when making an exposure. 57692 Front cover ArcBody. For camera body and Rodenstock lenses. 57695 Filter holder. General multi-compartment filter holder for all types of M77 standard filters, both 100x100 mm and 100x150 mm.
Hasselblad front pro tective cusing screen adapter it is advisable to keep the covers in covers. place for protection. Set up the ArcBody on a tripod or cam- era stand and proceed as follows: Removing a lens Front protective cover...
The screens are simply inserted into the slot in the The focusing screen adapter focusing screen adapter, only one screen at a time Rest the focusing screen adapter on the ArcBody’s being used. They may be inserted from the left or magazine supports ensuring that it is properly lo- the right but always so that the text can be read cated.
Correction slide– MEDIUM moval when the ArcBody is in the normal position. They are automatically secured in place by a catch For use when the amount of shift is no greater than on the focusing screen adapter that must be de- ca.
ArcBody, the combination becomes a complete camera. As there is viewfinder PME51/PME90 no mirror, the ArcBody behaves in the same manner as a view The prism meter viewfinders PME51( incl. earlier camera in the sense that a direct inverted image is formed on the...
Although removable, the Extension tube 26 fig. 18 indicates how to read the depth-of-field ArcBody is intended to be an integral part of the scale at an aperture of f /11 and a focus setting of Grandagon - N 4.5 /75 and must always be attached ca.
porarily, the holder can also be oriented at a Do not remove the slide from an at- 90˚click-stop position, or freely at any angle in the tached magazine before you have vertical plane. closed the shutter (open/close shut- ter lever). A deviation from the vertical orienta- tion of the filter holder may affect the When using large amounts of shift...
All Hasselblad film magazines are compatible with the age over the film plane. Its use is also recommend- ArcBody, thus providing you with a wide choice. 6x6 cm and ed with the 75 mm lens when maximum shift is 6x4.5 cm formats are catered for, 120, 220 and 70 mm perfo- being used.
has made contact with the camera body, and then The magazine status indicator push the button to the left to ensure that it has The status indicator on the right hand side of the reached the locked position. Remove the slide so magazine shows white when the magazine is ready that the magazine positively locks onto the camera to operate and red when the film has not been ad-...
– shift and tilt. It is these two move- straints of the bellows. Try to find a ments that the ArcBody utilises to exercise control compromise combination instead. over image shape and sharpness.
The column to the left (A) denotes the extension tube while the horizontal heading (B) refers to the The ArcBody is a very simple camera to operate, image scale range for each lens in three separate however, to avoid errors it is advised that you try to columns.
Page 39
5. Compose the photograph. Focus the camera by 14. Rest the magazine on the magazine supports, turning the lens barrel. A distance scale and ensuring it is properly located on them. depth-of-field scale are engraved on the lens to Carefully swing the magazine toward the cam- provide a rough guide and are sufficient for era body and check that the camera’s upper sup- general practice but of course the use of the fo-...
Shift and tilt, familiar terms to technical camera users, quick- respective positions on the film plane, fig 31.The ly become second nature to Hasselblad ArcBody photogra- solution to the problem is to alter these distances. phers too. A few minutes thought over the examples shown In fig.
The display an unacceptable amount of divergence at Hasselblad ArcBody is a powerful tool that can be the top of the picture. considered for a surprisingly large number of as-...
Solution: Mount the ArcBody at 90˚ with the ‘top’ pose the image on the focusing screen. Adjust the of the camera on your right hand side. Check to see focus again if necessary.
69–72 Solution: Set up the ArcBody at 90˚.With shift set 8.Problem: You want to take a portrait against a at the zero position, tilt the top of the rear standard specific background.
Page 44
There are limitations, however, as each lens has a specific circle of coverage. The Rodenstock lenses for the ArcBody have a large circle and can therefore allow a moderate amount of film plane placement within that circle. Both shift and tilt can...
Troubleshooting Problem Possible cause / remedy You cannot remove the lens. • Depress lens release button. There is no image on the focusing screen. • Lens cap still in place. • Shutter closed. You cannot produce a sharp image with the •...
Mechanical, with controls for tilt and shift. Film advance: Manual advance with winding crank. 1/4 ” and 3/8 ” socket threads and base plate for Hasselblad Tripod quick- Tripod coupling: coupling attachment. 60 x 145 x 160 mm (2.4 x 5.7 x 6.3”) – LxWxH - body only...
Equipment Care, Service and Guarantee EQUIPMENT CARE damage and care should be taken near pointed or sharp objects. The ArcBody is best stored with The ArcBody is designed to withstand the rigours the bellows in the ‘neutral’ position (10 mm shift of professional use in most environments.
Page 50
Product no: 17015, 17511 Hasselblad reserve the right to make changes in the published specifications without prior no- tice. All rights reserved. No part of this material may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, elec-...