Connecting To The Course Computer; Course Computer Connections - Raymarine Hydraulic Pump Installation Manual

Hydraulic pump
Table of Contents

Advertisement

Hydraulic Pump - Installation Guide

4. Connecting to the course computer

WARNING: Electrical safety
Make sure the power supply is switched off before you make any
electrical connections.
The hydraulic pump has electrical connections for its motor: a red and
a black cable.
Note: To meet current EMC legislation, you must NOT untwist the
pump cables, and you must NOT remove the suppression ferrite.
Follow these steps to connect the pump motor to the course computer:
1. Measure the distance of cable run from the pump to the course
computer, then use Table 2 to identify the appropriate cable sizes.
2. Join these cables to the ones on the pump using appropriate
electrical connectors or junction boxes at the correct power rating.
3. Route the cables back to the course computer, taking into account
the EMC installation guidelines (page 6).
4. Connect the cables from the pump to the MOTOR terminals on the
course computer (see Figure 8): at this stage you can connect
either motor cable to either terminal. You will check these
connections after installing the rest of the autopilot system.
Note: If installing the pump on a boat with mechanical steering, you
need to connect a bypass valve to the CLUTCH terminals (see page 14).
+
OFF
POWER
MOTOR
SWITCH
Type 150/400 course computer
Figure 8: Course computer connections
+
A
B
SOLENOID
CLUTCH
+
+
lk CLUTCH
POWER
Type 100/300 course computer
13
1
2
MOTOR
D5171-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M81120M81119M81121M81123M81122M81124

Table of Contents