Single- -Piece Installation
The following steps should be followed for the installation of the single- - piece
configuration.
1. Remove cover from Equipment Control Module by pressing the two tabs on
the bottom edge and pulling away. Route wires through large hole in Equip-
ment Control Module. Level Equipment Control Module against wall (for
aesthetic value only - - Equipment Control Module need not be leveled for
proper operation) and mark wall through 4 mounting holes.
2. Drill two 3/16- - in. mounting holes in wall where marked. Thermidistat Con-
trol may be mounted to a standard junction box if desired. Hole pattern on
Equipment Control Module matches junction box mounting holes.
3. Secure rear plastic Equipment Control Module to wall with 4 screws and
anchors provided. Additional mounting holes are available for more secure
mounting if needed. Make sure all wires extend through hole in Equipment
Control Module.
4. Adjust length and routing of each wire to reach proper connector block and
terminal on Equipment Control Module with 1/4- - in. (6mm) extra length.
See Fig. 15.