Cooper Lighting Metalux 2EP3GAX Series Specification Sheet

Cooper lighting air supply troffer specification sheet

Advertisement

Quick Links

D I M E N S I O N S
NOMINAL SIZE
A
1' x 4'
11-3/4" (298mm)
1' x 4' (OU)
11-3/4" (298mm)
2' x 2'
23-3/4" (603mm)
2' x 4'
23-3/4" (603mm)
20" x 24"
19-3/4" (502mm)
20" x 48"
19-3/4" (502mm)
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : 2 E P 3 G A X - 3 3 2 S 3 6 I - 1 2 0 V - E B 8 1 - U
2048= 20" Width
HM=Hard
x 48" Length
Metric
2024= 20" Width
HR=Heat
x 24" Length
(1)
Removal
Number
HRDO=Heat
of Lamps
Removal
1, 2, 3 or 4 lamps
Damper Open
(Not included)
HRDC=Heat
Removal
Wattage (Length)
Damper Closed
U6T8=31W T8 (24")
Width
17=17W T8 (24")
2'=2' width
U15/8=31W T8 (24")
Blank=1' width
BX40=40W Biax (24")
or 20" width
32=32W T8 (48")
EP=Paralux Louver
Louver Color
3=3" Louver Depth
S=Silver
W=White
Trim Type
G=Grid/Lay-in (Standard)
Cell Configuration*
G or T=Concealed T
(2)
(See below for Louver Options)
G or T=Slot Grid
F=Flange Trim
Louver Finish
MZ=Modular Trim
H=Semi-Specular/Haze (Gold only)
(3)
Convertible Fixture
Standard G (Grid)
I=Semi-Specular/Haze (Low Iridescent) Standard
Type-Fixtures can be field converted to
T-option or vice-versa. Fixture also
(Silver Only)
adaptable with flanged or modular trims.
MI=Specular/Mirrored (Low Iridescent) (Silver Only)
P=Painted (White only)
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver -
Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
P R O D U C T I N F O R M AT I O N F O R PA R A L U X I I I
Housing
Louver Cell
Size
Configuration*
1' x 2'
13, 14, 23, 24
1' x 4'
16, 18, 26, 28
2' x 2'
23, 33, 34, 44
20" x 24"
23, 24, 33, 34
20" x 48"
26, 36, 38
2' x 4'
26, 28, 36, 38, 46, 48
*Example: 36= 3 rows of 6 (18 cells)
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal.
housing only, appropriate shielding media assemblies must be utilized.
(6)
frequencies for international markets.
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
COOPER LIGHTING - METALUX
B
6-5/8" (168mm)
8-1/4" (210mm)
5-5/8" (143mm)
5-5/8" (143mm)
5-5/8" (143mm)
5-5/8" (143mm)
(5)
Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277
(4)
Options
GL=Single
Element Fuse
GM=Double
Element Fuse
WTR=White
Reveal
Lamps - for lamps
installed, see lamp
options table
Flex - for flex
installed, see flex
ordering table
Emergency - for
EM installed, see
EM options table
Number
of Cells
3, 4, 6, 8
6, 8, 12, 16
6, 9, 12, 16
6, 8, 9, 12
12, 18, 24
12, 16, 18, 24, 24, 32
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Standard off-center ballast on 3-lamp fixtures.
D E S C R I P T I O N
The Paralux III series features
recessed aesthetics and the
latest in energy efficient
technology. The luminaire
incorporates a 3" precision cell
louver into a nominal 5-1/2" deep
para-contoured fixture housing.
This combination creates a total
high performance parabolic
optical assembly for optimum
performance. The Paralux III
series offers balanced
illumination with reduced glare,
increased VCP's and excellent
shielding. The series is
compatible with all of today's
popular ceiling systems. The
Paralux III series is an excellent
choice for commercial office
spaces, schools, hospitals or
retail merchandising areas.
Packaging
Options
(See Options
U=Unit Pack
Section)
PAL=Job Pack,
out of carton
(5)
Ballast Type
PALC=Job Pack,
(6)
Blank=Standard Magnetic
in carton
Ballast (Biax & 20W)
LE3=T12 Magnetic Energy Saving
EB8 = T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
No. of
Harmonic Distortion < 20%
Ballast
1, 2 or 3
ER8 = T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB5 = T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
No. of Ballast
1, 2 or 3
TEB5 =T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB2 =T12 Electronic Rapid Start.
No. of Ballast
1 or 2
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify
manufacturer's ballast see pg. 469)
(3)
Convertibility applies to
(5)
Products also available in non-US voltages and
®
2EP3GAX SERIES
1 ' x 4 ' , 2 ' x 2 ' , 2 ' x 4 ' ,
2 0 " x 2 4 " o r
2 0 " x 4 8 " P a r a b o l i c
1 , 2 , 3 o r 4 L a m p
P a r a b o l i c L o u v e r
PA R A L U X I I I
R E C E S S E D S TAT I C O R
A I R S U P P LY T R O F F E R
• Equipped with energy
saving ballasts/complies
with federal energy
efficiency standards
• Computer designed,
precision cell louver
technology
• Field convertible feature
• Self locking spring loaded
cam latches/ T hinges
• Four auxiliary fixture end
suspension points provided
• Interlocking tabs and
screws secure end plates
• End plate grid-lock
feature
(1)
• Efficient air handling
options
DLS
Dimming Ballasts are
available
• Floating louver/black reveal
• For information on flanged
fixture, including ceiling
opening size, see Technical
Section.
• UL/CUL Listed. Suitable for
damp locations.
COOPER LIGHTING
391