Seagate EXOS ST10000NM018G Product Manual page 20

Table of Contents

Advertisement

www.seagate.com
S.M.A.R.T. Read Data Reports
Attribute 192 - Emergency Retract Count
Attribute 193 - Load/Unload Cycle Count
PowerChoice Manufacture Default Power Condition Timer Values
Default power condition timer values have been established to assure product reliability and data integrity. A
minimum timer value threshold of two minutes ensures the appropriate amount of background drive maintenance
activities occur. Attempting to set a timer values less than the specified minimum timer value threshold will result in
an aborted EPC "Set Power Condition Timer" subcommand.
Power Condition Name
Idle_a
Idle_b
Idle_c
Standby_z
Setting power condition timer values less than the manufacturer specified defaults or issuing the EPC "Go to Power
Condition" subcommand at a rate exceeding the default timers may limit this products reliability and data integrity.
PowerChoice Supported Extended Power Condition Feature Subcommands
EPC Subcommand
00
H
01
H
02
H
03
H
04
H
05
H
PowerChoice Supported Extended Power Condition Identifiers
Power Condition Identifiers
00
H
01 - 80
H
81
H
82
H
83
H
84 - FE
H
FF
H
Seagate Exos X18 SATA Product Manual, Rev. D
Manufacturer Default Timer Values
100 ms
2 min
4 min
15 min
Description
Restore Power Condition Settings
Go to Power Condition
Set Power Condition Timer
Set Power Condition State
Enable EPC Feature Set
Disable EPC Feature Set
Power Condition Name
Standby_z
Reserved
Idle_a
Idle_b
Idle_c
Reserved
All EPC Power Conditions
Drive specifications
19

Advertisement

Table of Contents
loading

Table of Contents