Te (Thermistor (Heating) Error) - LG WD14030D6 Service Manual

Hide thumbs Also See for WD14030D6:
Table of Contents

Advertisement

Thermistor (Heating) Error (tE)
Is the
Connector
connected correctly to
the
Main PCB
and the
Is the
Harness
alright ?
Heater for Washing
NO
Is the resistance of the
53 KΩ at 25°C? (Page 17)
NO
Is the resistance of the
28.5Ω (for Washing) or 42.5 ~ 49.5Ω (for Steam) ?
(Page 19)
NO
Replace the
Main
PCB.
[Note] Thermistor Spec
S
Resistance (kΩ)
Temp
P
MIN
E
30 °C
36.35
C
40 °C
24.20
60 °C
11.43
70 °C
8.088
95 °C
3.544
105 °C
2.617
Thermistor
and the Heater?
Heater for Steam
Thermistor
out of range 44 ~
Heater
out of range 24.5 ~
STD
MAX
39.45
42.72
26.05
27.97
12.12
12.82
8.514
8.940
3.791
4.045
2.816
3.023
YES
YES
YES
29
Reconnect or repair the Connector.
Or replace the Harness.
Replace the Thermistor.
Replace the Heater.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd14039d6

Table of Contents