Holmes HAP1702 - Allergen Remover Air Purifier With Filters Manual

Holmes HAP1702 - Allergen Remover Air Purifier With Filters Manual

Advertisement

Holmes HAP1702 - Allergen Remover Air Purifier With Filters Manual

FEATURES

POWER CORD INSTRUCTIONS

  • The length of cord used on this appliance was selected to reduce tangling or tripping hazards.
  • If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the electrical rating of the air purifier (see rating label marked on bottom of the product).
  • Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

GET TO KNOW YOUR AIR PURIFIER

This unit is compatible with all Aer1® Filters. This allows you to choose the filter that is just right for you. Below is information on each filter:

TOTAL AIR - Advanced Dust Eliminating Technology

ODOR ELIMINATOR - 10x the odor fighting power

ALLERGEN REMOVER - True HEPA technology improves air quality for allergy sufferers

ALLERGEN PERFORMANCE PLUS - True HEPA technology improves air quality for allergy sufferers.

SMOKE GRABBER - 99% effective at removing smoke from the air steam (*as small as 0.3 microns from air passing through the filter)

IONIZER

This appliance has an optional ionizer feature which, when turned on, releases negative ions into outgoing filtered air to help the air purification process.

What Are Ions?
Ions are tiny particles that carry a positive or negative charge. They exist naturally around us: in the air, water, and ground. Both positive and negative ions are colorless, odorless, and harmless.

How Does The Ionizer Work?
Negative ions help air purification by attaching themselves to very small airborne particles in the room. These particles take on a negative charge and may join with positively charged particles such as dust, pollen, smoke, and pet dander to form larger particles. These larger particles are then more easily captured by the filter system.

information Important Notes:
Your ionizer may produce an occasional popping or cracking sound. This is normal and occurs when a small buildup of ions is discharged.

After extended use, you may notice dust around the grills or front panel. This is caused by negative ions exiting the air outlet, evidence of the ionizer's air cleaning effectiveness. You can remove the dust with a soft brush or clean, damp cloth.

Larger particles may be attracted to positively charged surfaces throughout the home, like walls or floors.

  • This may occur more frequently when the filter is nearing the end of its useful product life and unable to capture as many charged particles.
  • Excessive amounts of pet dander, dust, or smoke may decrease the life expectancy of the filter and interfere with the ionization process.

To help prevent particles from attracting to surfaces throughout your home:

  • You may want to run the ionizer less often.
  • Check the condition of the filter more frequently.


The ionizer in this appliance produces less ozone than the UL established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the air purifier fan on.

HIGH, MEDIUM AND LOW SPEED SETTINGS

For optimum air filtration, operate your Holmes® air purifier continuously on the MEDIUM (Med) setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select the LOW (Lo) setting. When high levels of air pollution are present, select the HIGH (Hi) setting to quickly circulate and filter the room air.

AIR QUALITY SENSOR

Your Air Purifier is equipped with Air Quality Sensor to cycle between low, medium and high speeds, based on surrounding indoor air quality. Press Power /Mode button to select AQS setting, the air purifier will run on High upon startup in order to quickly analyze surrounding air quality. Once air quality has been determined, the unit may switch to a different fan/filtration speed for optimal filtration. An automatic adjustment in speed does not demonstrate that the air has been cleaned but does demonstrate that air quality has been determined and an optimal speed has been selected. The Air Quality Sensor may adjust fan/filtration speeds at varying rates as it continues to measure air quality during use.

FEATURES - OPERATIONS


FEATURES - OPERATIONS

  1. Speed Setting Indicator Lights
  2. Power/Mode Button
  3. Filter Reset Button/Light
  4. Timer Button
  5. Timer Indicator lights
  6. Ionizer Button/Light
  7. AQS Indicator Light
  8. Filtered Air Outlet
  9. Aer1 ® Filters
  10. Carbon Filters
  11. Washable Foam Pre-Filter
  12. Air Inlet Grill

FILTER CHECK INDICATOR

Your Holmes® Air Purifier includes Aer1® Allergen Performance Plus Filters, specially designed to improve air quality for allergy sufferers!! The Aer1® Allergen Performance Plus filter last for 12 months. See back panel for other filter options.

The Filter Check Indicator light is designed to remind you to check and change your filters every 11 months. To reset the Filter Check Indicator, press and hold the Filter Reset Button for 3 seconds only under working mode.

BEFORE USE

  1. Carefully unpack your Air Purifier. Select a firm level place where there are no obstructions to the air inlet or filtered air outlet.
  2. Remove the air inlet grill and check if the filter is covered by a plastic bag. If it is, remove plastic bag before use.
  3. The carbon filters are packed in a plastic bag in the box. Remove plastic bag, use the provided Velcro to attach the carbon filters onto the Aer1® filters. Then, place all filters back into the unit, and reinstall the air inlet grill (see Fig. 1).
  4. DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.

OPERATING INSTRUCTIONS

Plug into a 120V AC electrical outlet.

Power/Mode

  1. Press the /Mode button to start operations, the air purifier is default to run at LOW (Lo).
  2. Continue to press the /Mode button to cycle through all speed settings/mode:
    LOW (Lo) - MEDIUM (Med) - HIGH (Hi) – AQS
    Select the appropriate setting and the corresponding indicator light will illuminate to indicate which mode is activated. See below section for details of Air Quality Sensor Mode (AQS).

NOTE: For optimum air filtration, it is recommended to operate the air purifier continuously. Its rugged motor has been designed to give many years of use.

  1. To release negative ions into the filtered air, press the ionizer button () to ON and the button will illuminate in blue.

NOTE: The ionizer will not work unless the unit is running.

Air Quality Sensor Mode (AQS)

The AQS feature uses the particle sensor to cycle between low, medium and high speeds, based on surrounding indoor air quality. To activate AQS mode, press the / Mode button to select AQS and the AQS indicator light will illuminate in RED (default) and the unit will run at HIGH setting. The AQS indicator light will change in 3 colors to indicate different indoor air quality conditions, and the speed setting will be changed automatically based on the current indoor air quality:

RED – Poor air quality: The unit will run at HIGH setting to improve air quality

YELLOW – Average air quality: The unit will run at MEDIUM setting to maintain air quality

GREEN – Good air quality: The unit will run at LOW setting to achieve energy saving.

NOTE: When AQS mode is activated, only the AQS indicator light will illuminate, all the other speed setting indicator lights (Hi/Med/Lo) will go off under AQS mode.

Timer

You may set the timer so it automatically turns off when the desired time has elapsed:

  1. Press the TIMER () button to select the desired number of hours you want the unit to operate (2Hr, 4Hr, 6Hr or 8Hr):
  • The corresponding indicator light will illuminate to indicate which timer option is selected.
  • When the air purifier is running up to the set time, the air purifier will turn off automatically.
  1. To CANCEL the timer, press the TIMER button until TIMER indicator lights go off.

CLEANING/MAINTENANCE FILTER REPLACEMENT

CLEANING/MAINTENANCE INSTRUCTIONS

  1. Turn the air purifier off and unplug it before cleaning.
  2. The outside of the air purifier can be cleaned with a soft, clean dampened cloth.
  3. The air inlet grill (reference Fig. 1) can be removed and washed in warm soapy water (not dishwasher safe). Dry before replacing in the unit.
  4. The filtered air outlet can be cleaned of dust with a small, soft brush.
  5. If you wish to clean the inside of the air purifier, please only use a dry, soft cloth to wipe it down.


Do not allow moisture to come in contact with the main housing of the air purifier.

FILTER REPLACEMENT INSTRUCTIONS

  • DO NOT attempt to wash and re-use the Aer1® Filters.
  • If the filters are enclosed in plastic bags, remove them before use.

NOTE:
Every few weeks, check the condition of filters. Filter life will vary, depending on air quality and usage (see below). Under normal conditions of continuous use, the Aer1® Total Air, Odor and Smoke Filter will last 4 months while the Allergen and Allergen Performance Plus Filter will last 12 months. Check the condition of the Carbon Filters for every 3-4 months and replace if needed. Carbon filters need to be replaced every 60-90 days.

After approximately 11 months of operation, the Filter Check Indicator will light up to alert you to service the filters.

  • This Filter Check indicator is to remind you to wash the foam pre-filter and replace your Aer1® Filters and carbon filters.

Filters can be purchased at a retailer near you, online at www.aer1filters.com, or by calling (855) Try-aer1.

Air Purifier Model Number Filter Quantity Needed Compatible with all filter models below Filter Description
HAP1702 2 HAPF30AT
HAPF30AO
HAPF30AS
HAPF300AH
HAPF300AP (D filter) H
APF30 (A filter)
aer1® Total Air Filter
aer1® Odor Filter
aer1® Smoke Grabber Filter
aer1® Allergen Remover Filter
aer1® Allergen Performance Plus "D" Filter
Holmes® "A" Filter
2 AOR31 Carbon Filter

FILTER REPLACEMENT TROUBLESHOOTING

To replace your filters:

  1. Turn off and unplug the air purifier.
  2. Open the air inlet grill and examine the black foam prefilter. Remove any dust or lint and wash in warm soapy water. Rinse, drip dry and place back into grill inlet.
  3. Remove the used Aer1® filters and carbon filters from the unit by pulling it gently towards you and discard it. DO NOT attempt to clean the Aer1® filters.
  4. To replace the carbon filters, simply remove the old carbon filters with the Velcro, and insert new carbon filters in place after first removing the plastic bag. Using the new Velcro provided with the carbon filters to attach the new carbon filters onto the new Aer1® filters.
  5. Install the new Aer1® filters into the unit. (Fig. 2)
  6. Align the clip on the side of Aer1® filter with rails on the inside of the purifier unit. Gently slide the filter onto the rail. (Fig. 2)
  7. Replace air inlet grill.
  8. To reset the Filter Check Indicator, press and hold the Filter Reset Button for 3 seconds only under working mode when unit is powered on.
    NOTE: Every time you power on the air purifier by selecting any speed setting, the Filter Check checks the current usage of the filters. If the filter timer has not reached the filter life, the indicator light will go off. If not, the indicator will remain lit until filters have been replaced and Filter Check Indicator () has been reset (see instructions above).
TROUBLESHOOTING
Problem Solution

Unit will not operate

Check if unit is properly plugged in and outlet is energized.

Make sure unit turned ON.

Make sure filters are properly installed and rear grill is seated correctly.

Decreased air flow

Make sure nothing is blocking air inlet and filtered air outlets.

Check condition of the filters and replace if necessary.

Check filters to remove any plastic wrapping/packaging.

Ensure carbon filters are changed every 60-90 days.

Excessive Noise

Make sure parts are firmly positioned in place.

Open the air inlet grill and make sure that any plastic packaging was removed from the filters, if applicable.

The filter check indicator will not reset

Check condition of the filters and replace if necessary.

Press and hold the Filter Reset Button for 3 seconds under power on condition.

Speed Setting changes automatically

Check if unit is on AQS setting.

LEARNING MORE

For a wealth of information about your air purifier and other Holmes® products, visit our website at www.holmesproducts.com or call 1-800-546-5637. For inquiries regarding recycling and proper disposal of this product, please contact your local waste management facility.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Holmes HAP1702 - Allergen Remover Air Purifier With Filters Manual

Advertisement

Need Assistance?

Do you have a question about the HAP1702 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents