Download Print this page

Dometic NDR 1292 Installation And Operating Instructions Manual page 13

Advertisement

THERMOCOUPLE
FIG. 12
BURNER TUBE
SPARK ELECTRODE
column. The correct place to take the LP gas pres-
sure is at the test port just ahead of the burner jet.
(See FIG. 12).
E. Inspect the flue baffle. It should be reasonably clean
and free of soot. Heavy soot formation indicates
improper functioning of the burner. The flue and
burner both require cleaning in the following manner:
1.
Unplug the refrigerator power cord from the 120 volt
AC outlet. (See FIG. 3).
2.
Disconnect or shut off the 12 volt power to the
refrigerator.
3.
Turn manual shutoff valve to OFF. (See FIG. 1).
4.
Remove cover from the burner housing. (See FIG.
1).
5.
Disconnect the wire from the high voltage electrode.
6.
Remove the burner mounting screws and remove the
burner assembly. (See FIG. 12).
7.
Remove the wire and the flue baffle from the top of
flue tube. Clean the flue from the top using a flue
brush. Blowing compressed air into the flue will not
properly clean soot and scale out of the flue tube.
Replace the flue baffle.
8.
Clean burner tube with a brush. Blow out burner with
compressed air.
9.
Before removing burner jet, clean burner area of soot
and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Re-install and tighten burner jet.
NOTE: The color of the flame shall be clear blue over
the slots of the burner. (See FIG. 13).
FIG. 13
GAS EQUIPMENT ASSEMBLY
BURNER MOUNTING SCREWS
BURNER JET
Clear blue color
of flame
SOLENOID VALVE
MANUAL SHUT OFF VALVE
Shown in open position.
PRESSURE TEST PORT
! WARNING
DO NOT use a wire or pin when cleaning the burner
jet as damage can occur to the precision opening.
This can cause damage to the refrigerator or create
a fire hazard.
10. Reinstall burner, being careful that the end of the
burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).
11. Be sure to reconnect the wire to high voltage elec-
trode. Check the electrode for proper location and
gap. (See FIG. 14).
FIG. 14
1/8" to 3/16"
(3-5 mm)
12. Turn on manual gas shutoff valve and check all
fittings for leaks.
13. Connect 120 volt power cord to the outlet and recon-
nect or turn on the 12 volt DC power.
14. Check LP gas safety shutoff. See page 6.
INLET FITTING
Electrode
Burner tube
13

Advertisement

loading