Controlling the Monitor with a PC (RS-232C)
Commands for setting of the GAMMA user data
Function
RED GAMMA DATA TRANSFER
GREEN GAMMA DATA TRANSFER
BLUE GAMMA DATA TRANSFER
RED GAMMA DATA READ
GREEN GAMMA DATA READ
BLUE GAMMA DATA READ
USER DATA INITIALIZE
USER DATA SAVE
52
E
Command
Direction
Parameter
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
UGGW
W
aa: 01-16
UGBW
W
xxxx: 0000-1023
cc: 00-FF
UGRR
W
1-16 xxxx ··· xxxx
UGGR
W
1-16
UGBR
W
1-16
UGRS
W
0
UGSV
W
0
Reply
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
xxxx: User data of 32 pieces
(xxxx: 32 pieces)
xxxx: 0000-1023
Initialize the user data.
Save the user data in the monitor.
Control/Response contents
*