Download Print this page
Cooper Lighting IMI-694 Installation Instructions
Cooper Lighting IMI-694 Installation Instructions

Cooper Lighting IMI-694 Installation Instructions

Cooper lighting parking luminaire installation instructions

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS

IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE
GENERAL: Upon receipt of luminaire thoroughly inspect for any freight
damage, which should be brought to the attention of the delivery
carrier. Compare the catalog description listed on the packing slip
with the luminaire label on the housing to assure you have received the
correct merchandise.
SAFETY: This luminaire must be wired in accordance with the national
electrical code and applicable codes and ordinances. Proper grounding
is required to insure personal safety. Carefully observe grounding
procedure. All work should be done by a qualified electrician.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR
DEATH
NOTE : Use minimum 90°C supply wire rating for connections in J-box.
Fixture Orientation Guideline:
Proper orientation of luminaire may vary based upon design requirements
specified per given application. Labels are supplied on top of fixture and
mounting plate for reference to proper fixture alignment. Align quick mount
plate in correct direction by referencing number of fixtures required (double or
single row luminaire installation) to direction of arrows. Direction of arrow(s)
should be in line with direction of traffic.
LUMINAIRE INSTALLATION:
1. Install quick mount plate on a 4" junction box as shown in (Figure 1).
Note the required position of plate to ensure correct light beam
orientation from fixture. See guidelines above or labels on top of fixture
housing and mounting plate if applicable.
2. Secure hanging hook into the rear hooks of quick mount plate
(Figure 2 & 3).
3. Make wiring connection while luminaire is being suspended from hanging
hook.
4. Push excess wires and connectors up into the junction box through center
access hole.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user's purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
8/20/08
WARNING: Make certain power is OFF before starting installation or
attempting any maintenance.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit
breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow luminaire to cool
before changing lamp or handling luminaire.
WARNING: This luminaire is for use with downlight applications only.
WARNING: RISK OF FIRE! DO NOT mount on or near combustible
materials.
Figure 1
J-BOX
CENTER ACCESS
HOLE
#8-32 SCREW
Figure 2
J-BOX
QUICK MOUNT
PLATE
REAR HOOKS
LUMINAIRE
HANGING HOOK
Figure 3
LIFT UP
THEN PUSH
LUMINAIRE
BACK
ADH080771
EPL Envoy
Parking Luminaire
Sheet 1 of 5
IMI-694
QUICK MOUNT
PLATE
FRONT HOOKS
J-BOX
HANGING
HOOK
LUMINAIRE

Advertisement

loading

Summary of Contents for Cooper Lighting IMI-694

  • Page 1: Installation Instructions

    WARNING: RISK OF FIRE! DO NOT mount on or near combustible materials. Figure 1 J-BOX CENTER ACCESS HOLE #8-32 SCREW Figure 2 J-BOX QUICK MOUNT PLATE REAR HOOKS LUMINAIRE HANGING HOOK Figure 3 HANGING HOOK LIFT UP THEN PUSH LUMINAIRE BACK ADH080771 IMI-694 QUICK MOUNT PLATE FRONT HOOKS J-BOX LUMINAIRE...
  • Page 2 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 EPL Envoy Parking Luminaire Sheet 2 of 5 8/20/08 Figure 4 TAMPER-PROOF SCREW FOR HANDLE Figure 5 TO REMOVE HANDLE ADH080771 IMI-694 TAMPER-PROOF SCREW FOR LATCH...
  • Page 3: Lamp Installation

    OF LENS BEFORE LATCHING Figure 10 PUSH TO LATCH SUPPORT LENS WHILE IT SWINGS OPEN ADH080771 EPL Envoy Parking Luminaire Sheet 3 of 5 8/20/08 IMI-694 ALIGN THESE RIBS AS SHOWN BEFORE LATCHING (OTHER SIDE NOT SHOWN) LATCH PUSH TO LATCH...
  • Page 4 FOR VERTICAL ADJUSTMENT (UP OR DOWN ONLY) 8-3/8 TO 13-1/4” FROM TOP OF LUMINAIRE Figure 12 HANDLE (APPLY SEALING COMPOUND BY OTHERS) TASK LIGHT HEAD #10-24 ALLEN HEAD LOCK NUT ADH080771 IMI-694 COVER #10-24 FLAT CS SCREW BOTTOM TRUNNION HOUSING ADAPTER...
  • Page 5 (BY OTHERS) KNOCK-OUT FEATURE Figure 14 KNOCK-OUT FEATURE WIRE TIE (BY OTHERS) CONDUIT PIPE KNOCK-OUT FEATURE ADH080771 IMI-694 #10-24 X 5/8 TAPTITE SCREW (BY OTHERS) WIRE TIE (BY OTHERS) KNOCK-OUT FEATURE THRU-BRANCH FEATURE CONDUIT PIPE KNOCK-OUT FEATURE #10-24 X 5/8 TAPTITE...

This manual is also suitable for: