INSTALL THE PROTECTOR SYSTEM

NOTE: This accessory must be used for all
installations where the closing force as measured
on the bottom of the door is over 400 N (40 kgf).
After the opener has been installed and adjusted, the
Protector System™ can be installed. Instructions are
included with this accessory.
The Protector System™ provides an additional
measure of safety against a small child or animal
being trapped under a garage door. It uses an infra-
red beam, which when broken by an obstruction,
causes a closing door to stop and open, preventing an
open door from closing and is strongly
recommended for homeowners with young
children or pets.
ENABLING THE PROTECTOR SYSTEM:
• Connect the obstruction detection beam wiring to the opener and turn ON. (The obstruction detection
beams will automatically enable once they are connected and will now operate in a FAIL SAFE mode.)
DISABLING the obstruction detection beams:
If the obstruction detection beams are installed and needs to be removed the opener will need to be
reprogrammed.
Perform the power ON/OFF sequence as follows
• Remove the obstruction detection beam wires from the opener
• Turn the mains power OFF for 5 seconds
• Turn the power ON for 5 seconds
• Turn the power OFF for 5 seconds
• Turn the power ON and check the opener operates OK without the obstruction detection beams
Whilst Merlin have engineered safety features into your garage door opener, we urge you to
consider fitting obstruction detection beams to your new garage door opener. In many countries
these devices are compulsory to assist in preventing serious injury or property damage. For your
own peace of mind and the safety of others please consider installing this safety device.
Timer to close feature (TTC)
Auto close is NOT recommended for households with young children.
TIMER TO CLOSE feature: (TTC) 10 to 180 seconds.
NOTE: The Protector System
The Timer to Close feature allows the door to automatically close after a specified time period. During the
OPEN door waiting period, the courtesy light will flash continuoulsy.
If the door encounters an obstruction while closing, the opener will
return to the OPEN position and the waiting period will begin again.
To activate the Timer to Close:
• Start with obstruction detection beams installed and the door fully
CLOSED
• Press and Hold both "P" and "DN" buttons for 3 seconds. When the
Courtesy light flashes "TWICE", release both buttons
• Press the "UP" for each 10 second interval required for
Timer to Close. A "BEEP" will register for each press. "DN" button
will reduce the count if needed.
• Press and release the "P" button to accept this setting
To deactivate the Timer to Close:
• Start with the door fully CLOSED
• Press and Hold both "P" and "DN" buttons for 3 seconds. When the
Courtesy light flashes "TWICE", release both buttons.
• Press and release the "P" button to accept this setting
The door may operate unexpectedly, therefore do not allow anything to obstruct the path of the
door.
TM
(OPTIONAL ACCESSORY)
SAFETY FIRST!
TM
MUST be installed before TTC will operate.
10
Flash x 2
ACTIVATE
TIMER TO
1 1
DN
DN
3 3
2 2
UP
UP
P P
CLOSE
SET
1 1
DN
DN
3 3
TIME
2 2
UP
UP
P P
Flash x 2
ACCEPT
1 1
DN
DN
SETTING
UP
UP
2 2
P P
S S
S S
3 3
S S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr855evo

Table of Contents