PROPANE CONSTRUCTION HEATER
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO
50 ppm
CO
5000 ppm
2
NO
2
USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO
CO
2
NO
5 ppm
2
• Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
• As the building 'tightens up' during the construction phases ventilation may need to be increased.
Model   N o.
Input   R ating
Type   o f   G as
Gas   S upply   P ressure   t o  
Regulator   M aximum
Minimum   ( for   p urpose   o f  
Input   A djustment)
Manifold   P ressure
Gas   C onsumption
Electrical   I nput
Amperage
    L oad
    U nload
Fan
    L oad
Ignition
Spark   G ap
Size   ( LxWxH)
Canada 8-hr time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
Canada STEL (15 minutes Reg 833/1 hour
WSBC) WorkSafe BC OHS Guidelines Part
5.1 and Ontario Workplaces Reg 833
SPECIFICATIONS
FA40 Series
FA60   S eries
30,000   B TU/hr
40,000   B TU/hr
60,000   B TU/hr
Propane
Cylinder   P ressure
Cylinder   P ressure
5psig
11"   W .C
1.4lbs/hr               0 .63   k g/hr
1.9lbs/hr                 0 .86   k g/hr
2.8lbs/hr               1 .27   k g/hr
120V,   6 0Hz,   1 Ø  
120V,   6 0Hz,   1 Ø  
0.68amps
0.65amps
3550rpm
3000rpm
Piezo/Manual   S park
Continuous   S park
0.16"   ( 4mm)
0.16"   ( 4mm)
19.3"x8.3"x13.5"
19.3"x8.3"x13.5"
(49.0x21.1x34.2)cm
(49.0x21.1x34.2)cm
25 ppm
5000 ppm
3 ppm (Reg 833)
100 ppm
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
FA125 Series
70,000   B TU/hr
125,000   B TU/hr
Propane
Propane
Cylinder   P ressure
5psig
5psig
11"   W .C
11"   W .C
3.3lbs/hr           1 .5   k g/hr
5.8lbs/hr           2 .63   k g/hr
120V,   6 0Hz,   1 Ø  
0.7amps
3570rpm
3580rpm
3300rpm
3300rpm
Continuous   S park
0.16"   ( 4mm)
26.2"x11.8"x15"
(66.6x30.0x38.1)cm
25.6"x11.8"x15"
(65.0x30.0x38.1)cm
FA150 Series
120,000   B TU/hr
150,000   B TU/hr
Propane
Cylinder   P ressure
5psig
11"   W .C
5.6lbs/hr               2 .54   k g/hr
7.0lbs/hr               3 ,18   k g/hr
120V,   6 0Hz,   1 Ø  
0.7amps
3580rpm
3300rpm
Continuous   S park
0.11"   ( 2.8mm)
25.6"x11.8"x15"
(65.0x30.0x38.1)cm
4

Hide quick links: