Fault Finding - Bosch Worcester Greenstar Si Compact ErP User Instructions

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

7

Fault finding

In the event that the appliance stops functioning or does not perform as expected, please see table below These problems are some
of the most common causes. Should the problem persist or if other fault codes are displayed, then it will be necessary to contact
Worcester, Bosch Group.
This table gives information on basic operating system problems.
Problem
EA fault code flashing on
display
Desired room
temperature is not
reached
Desired room
temperature too high
Radiators are too hot
Heating stays on for too
long
No blue Operation/Fault
Indicator demand
Hot water temperature
too low
Hot water temperature
too high
Table 3
Fault finding
Greenstar Si Compact
- 6 720 813 279 (2014/09)
ErP
Cause
No gas supply/low gas supply pressure
Condensate outlet blocked
Flue blocked
Thermostatic radiator valve(s) set too low ▶ Increase thermostatic radiator valve setting(s).
Temperature control for central heating
flow on appliance set too low
Low temperature setting on the room
thermostat
Air trapped in heating system
Low system water pressure
Thermostatic radiator valves are set to high ▶ Turn down thermostatic radiator valves.
Room thermostat is set too high
Temperature control on appliance set too
high
Clock is incorrectly set
Momentary power failure
Heat requirement demand operation on
light has been deactivated
Temperature set too low on boiler controls ▶ Check setting and adjust
Water flow at tap too high
Air trapped in heating system
Low system water pressure
Temperature set too high on boiler controls ▶ Check setting and adjust
Water flow at tap too low
Remedy
▶ Contact your gas supplier.
▶ If it is safe to do so, check your condensate pipe
outlet for blockages, such as ice or foreign objects.
▶ If it is safe to do so, check your flue outlet for damage
or blockages.
▶ Increase central heating flow temperature control
setting
▶ Increase setting on the room thermostat.
▶ Bleed radiators and re-pressurise the heating system
▶ Re-pressurise the system, refer to page 11
▶ Turn down room thermostat.
▶ Reduce central heating temperature by turning down
the Central Heating control on appliance.
Note: This could prevent your property reaching the
desired temperature during cold weather periods.
▶ Check clock setting and adjust
▶ Disconnect boiler supply, wait a few seconds then
reconnect.
▶ Ask your installer to reset the blue light
▶ Reduce flow rate at tap
▶ Bleed radiators and re-pressurise the heating system
▶ Re-pressurise the system, refer to page 11
▶ Increase flow rate at tap
Fault finding
17