Download Print this page

First Alert PR700A Specification Sheet page 2

Advertisement

TOP VIEW
5.2"
ARCHITECTURAL AND ENGINEERING SPECS
The smoke alarm shall be a First Alert Model PR700A (Cat. 1039769) and shall
provide at a minimum the following features and functions:
1. A photoelectric smoke sensing chamber.
2. The unit shall be capable of self restoring.
3. A fully screened sensing chamber to resist entry of small insects thereby
reducing the probability of unwanted alarms.
4. Powered by a replaceable 9V battery and a solid state piezo horn rated at
85dB at 10 ft.
5. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
6. A full function test button. The test button should check all alarm functions
by stimulating the chamber to simulate a smoke condition, causing the unit
to alarm.
7. Silence feature - Temporarily silence unwanted nuisance alarms.
8. A tamper resistant locking pin that locks alarm to the mounting bracket to
prevent removal of battery.
9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C)
and relative humidity between 10% and 90%.
10. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
11. The unit shall at a minimum meet the requirements of ULC S531, NFPA 72,
NFPA 101, and ICC.
12. The unit shall have an "End of Life" signal.
INSTALLATION OF ALARM
Installation of this smoke alarm must conform to NFPA 72. Always check your
local building codes. Follow all instructions for placement as outlined in the
user's manual in sections titled "Recommended Locations for Smoke Alarms"
and "Locations to Avoid for Smoke Alarms."
THE PARTS OF THIS ALARM
2
1
1. Test/Silence button
2. LED alarm light
3. Install 9V battery here
4. Locking tab slot (Break out Tab)
MOUNTING
BRACKET
SIDE VIEW
1.13"
7
5. Mounting bracket
6. Mounting Slots
7. Horn
TECHNICAL SPECS
Alarm Dimensions:
Weight:
Operating Voltage:
Temperature Range:
Humidity Range:
Audio Alarm:
Test/Silence:
Alarm Reset:
Smoke Sensor:
Indicator Lights/Sounds:
DC Power:
Local Alarm:
End of Life:
Listing:
SHIPPING SPECS
Individual Carton Dimensions
Weight:
Cube:
UPC:
Master Carton Dimensions
Master Pack:
Weight:
Cube:
I2of5:
Pallet Information
Cases per Layer:
Number of Layers:
Cases per Pallet:
Units per Pallet:
Cube:
Weight:
3
Model PR700A
Cat. 1039769
5.2" Dia. x 1.13" H
6.0 oz
9V Battery Powered
40°F (4°C) to 100°F (38°C)
10% to 95% relative humidity (RH)
85dB at 10 feet
Electronically simulates smoke condition,
causing the unit to alarm. Press and hold
test/silence button.
Automatic when smoke clears
Photoelectric
Intermittent Red LED
Audio alarm and rapidly flashing Red LED
Horn sounds 5 chirps; pattern repeats
once/minute
Certified to ULC STD S531
6.8" L x 2.6" W x 8.5" H
0.5 lbs.
0.1 ft
3
0 29054 01856 4
7.3" L x 14.7" W x 9.0" H
6
3.92 lbs.
0.6 ft
3
300 29054 01856 5
15
5
75
450
55.6 ft
3
324 lbs.
4
6
5
4
© 2021 BRK Brands, Inc. All rights reserved. Distributed
by BRK Brands, Inc., Aurora, Illinois 60504. BRK Brands,
Inc. is a subsidiary of Newell Brands Inc. (NASDAQ: NWL).
brkcanada.ca
6
REV 11/20