15/18/24 class
[Method of mounting conduit]
1) Dismount the service lid by removing the 2 screws.
2) Pass wires through the conduit and secure them with a lock nut.
3) After completing the work, reattach the service lid to its original position.
1
2
3
L
1
L
2
Conduit mounting plate
Lock nut
Conduit
CAUTION
Precautions to be taken for power supply wiring
• When using stranded wires, make sure to use the round crimp-style
terminal for connection to the power supply terminal block.
Flat washer
Screw
• When connecting the inter-unit wires to the terminal block using a single core wire, be sure to curl the end of the lead.
I mproper work may cause heat and fires.
Good
Stripping wire at terminal block
English
Power supply
terminal block
Shape wires so
that the protection
plate and conduit
mounting plate fit
securely.
A
Round
crimp-style
terminal
Wrong
1
2
3
Round crimp-style
terminal
Screw
Round crimp-
style terminal
Flat washer
Good
A
Arrow view
Strip wire end
to this point.
Good
Service lid
Screws
Stranded wire
Screw
Flat washer
Round crimp-
style terminal
Wrong
Excessive strip length
may cause electric shock
or current leakage.
Wrong