ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit's AIR FLOW DIRECTION button.
Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.
Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction
louvers are stopped.
Vertical Air Flow Direction Adjustment
Press the AIR FLOW DIRECTION button (Fig. 6 Q).
Each time the button is pressed, the air direction range will change as follows:
1
Types of Air flow Direction Setting:
1,2,3
: During Cooling/Dry Modes
1,2,3,4,5,6
: During Fan mode
The Remote Control Unit's display does
not change.
G
Use the air direction adjustments within the ranges shown above.
G
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Fan mode
G
During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this pe-
riod.
Right-Left Adjustment
Adjust the Right-Left louvers.
G
Move the Right-Left louvers to adjust air flow in the direction you prefer.
knobs (three places)
En-9
2
3
4
5
: Downward flow 6
6
knob
DANGER!
G
Never place fingers or foreign objects
inside the outlet ports, since the internal
fan operates at high speed and could
cause personal injury.
G
Always use the remote control unit's
AIR FLOW DIRECTION button to adjust
the vertical airflow louvers. Attempting
to move them manually could result in
improper operation; in this case, stop
operation and restart. The louvers
should begin to operate properly again.
G
During Cooling and Dry modes, do not
move the vertical air direction louvers
outside their proper operating range
for the mode (1 - 3) and into the fan
region (1 - 6); using the louvers in
the fan region will cause moisture to
condense near the air outlet, and wa-
ter may drop onto the floor. During the
Cooling/Dry modes, if the louvers are
operated outside the range 1 - 3 for
more than 30 minutes, they will be
automatically returned to the 3 range.
G
When used in a room with infants, chil-
dren, elderly or sick persons, the air
direction and room temperature
should be considered carefully when
making settings.