Dyna-Glo KWD215 Manual page 20

Vent-free infrared gas wall heater
Table of Contents

Advertisement

OPERATION
If the control knob does not pop up when released, stop and immediately and call your service
technician or gas supplier.
8. Turn on all electric power to the appliance.
9. Turn control knob counter clockwise
THERMOSTAT GAS CONTROL
1. STOP! Read the safety information on the previous page.
2. Turn off all electric power to the appliance.
3. Turn control knob clockwise
4. Wait (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow "B" in the safety
information above. If you don't smell gas, go to the next step.
5. Turn knob counterclockwise
(See Fig. 23b) Depress control knob.
6. With control knob depressed, repeatedly push down the piezo ignitor
until the pilot lights. The pilot is visible, centered below the main
burner, behind the glass panel. (See Fig. 24 on page 19)
• Do not attempt to light the pilot by hand.
7. Keep control depressed for (30) seconds after pilot lights. Release
control knob.
Note: If pilot goes out repeat steps 3 through 7. Wait (1) min-
ute before attempting to light pilot again. If after several tries
the pilot still goes out, turn the gas control knob clockwise
to the "OFF" position and call your service technician or gas
supplier. If the control knob does not pop up when released,
stop and immediately and call your service technician or gas
supplier.
8. Turn on all electric power to the appliance.
9. Turn control knob counter clockwise
LIGHTING INSTRUCTIONS
to HIGH "
Burner Patterns (Manual Control)
to "OFF" position. (See Fig. 22b)
to the "PILOT" position.
to desired setting.
19
" setting.
Fig. 24 - Pilot Flame Location
OFF
ON
Fig. 22b
Fig. 23b