If the door is opened while the stove is in operation
it must be closed within 30 seconds or the stove
will shut down. If the stove shuts down push the
"On/Off" button to re-start your stove. The stove will
have to fully shut down and turn off before you will
be able to restart the stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not
come on until the stove's heat exchanger warms up.
This usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers
will run until the stove cools. This will take 30 minutes
or longer depending on the heat remaining in
the appliance. After the stove components stop
running all lights on the display will go out and the
two digit display will begin flashing "E3"
REFUELLING
CAUTION:
• THE HOPPER AND STOVE TOP WILL BE
HOT
DURING
OPERATION;
YOU SHOULD ALWAYS USE SOME TYPE
OF HAND PROTECTION WHEN REFUELING
YOUR STOVE.
• DO NOT TOUCH THE HOT SURFACES OF
THE STOVE. EDUCATE ALL CHILDREN ON
THE DANGERS OF A HIGH-TEMPERATURE
STOVE. YOUNG CHILDREN SHOULD BE
SUPERVISED WHEN THEY ARE IN THE SAME
ROOM AS THE STOVE.
• NEVER PLACE YOUR HAND NEAR THE
AUGER WHILE THE STOVE IS IN OPERATION.
• WE RECOMMEND THAT YOU NOT LET THE
HOPPER DROP BELOW 1/4 FULL.
WARNING:
• KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
• DO NOT OVERFILL HOPPER.
© 2022 United States Stove Company
OPERATION INSTRUCTIONS
TAMPER WARNING
This wood heater has a manufacturer-set minimum
low burn rate that must not be altered. It is against
federal regulations to alter this setting or otherwise
operate this wood heater in a manner inconsistent
with operating instructions in this manual.

SHUTDOWN PROCEDURE

NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
Turning your stove off is a matter of pressing the
"POWER" button on the display board. The green
light will turn back to red when the "POWER"
button is pushed. The auger motor will stop, and the
blowers will continue to operate until the internal
firebox temperatures have fallen to a preset level.
1.
Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset
thermodisc. This safety switch has two functions.
A. To recognize an overheat situation in the stove
and shut down the fuel feed or auger system.
THEREFORE,
B. In
blower, the high-temperature thermodisc will
automatically shut down the auger, preventing
the stove from overheating.
NOTE: On some units, once tripped, like a circuit
breaker, the reset button will have to be pushed
before restarting your stove. On other units the
thermodisc has no reset button and will reset
itself once the stove has cooled. The manufacturer
recommends that you call your dealer if this occurs
as this may indicate a more serious problem. A
service call may be required.
2. If the combustion blower fails, an air pressure
switch will automatically shut down the auger.
NOTE: Opening the stove door for more than
30 seconds during operation will cause enough
pressure change to activate the air switch, shutting
the fuel feed off. The stove will shut down and show
"E2" on the two digit display. The stove has to fully
shut down before restarting.