Page 1
SSI000/001/002/003/004/005/006/007/008/009/010/011 12 and 24V Modified Sine Wave Inverter User Manual IMPORTANT NOTICE: This product is not intended to be use by children or persons in poor health without supervision. Please read this manual thoroughly before use. CAUTION: Each model is design to work up to its maximum rated power load.
INTRODUTION: Thank you for choosing this Modified Sine Wave Inverter. This inverter is capable of converting DC power input to AC power output that has similar output signal wave as normal domestic mains. Unlike pure sine wave inverters, modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment.
FRONT PANEL: ON/OFF SWITCH – rocker switch to switch unit on and off POWER INDICATOR – solid green LED indicates unit has been switched on FAULT INDICATOR – solid on or flashing red LED indicates fault has occurred, refer to fault code for interpretation USB POWER SOCKET –...
Page 4
Mounting – The unit should be mounted horizontally; we do not recommend mounting the unit vertically. Connection: Please ensure the ON/OFF switch on the inverter is in the OFF position and the voltage of power source matches the required inverter input voltage, if the power source is from a DC power supply please ensure it is switched off also Connect the invert to battery / DC power source.
Page 5
For running the inverter on a DC power supply, it is important the check the current from power source is sufficient to run the inverter at full load. The required current to allow the inverter to operate at full load can be estimated from the continuous output power of the inverter and input power voltage.
24V OUTPUT – SERIES CONNECTION (voltage increase current remain) 24V OUTPUT – SERIES/PARALLEL CONNECTION (both voltage and current increase) SAFETY INSTRUCTION: Please note the following instructions should be carefully followed as any incorrect installation or misuse of the inverter may cause harm to user and damage apparatus. Do not connect any other form of input power other than DC power that is within the inverter’s acceptance range Ensure the ventilation duct on both front and back panels are clear of blockage when the inverter...
when in use, please discontinue use immediately and contact technician or retailer This inverter is design to be maintenance free, but requires occasional attention as dust may build up after period of time. To clean dust off, please switch off power from inverter and unplug AC plug.
TROUBLESHOOTING REFERENCE SYMPTOM POSSIBLE CAUSE SOLUTIONS 1. Check the continuity of the DC power input, ensure all batteries are working or DC power supply is on. There is no DC power from 2. Check that the battery inline fuse is intact. Replace if ON/OFF switch is the input terminals blown.
INTERFERENCE: It is not suggested to use modified sine wave inverter to power acoustic equipment. As the modified sine wave power signal will induce distortion signal to the sound signal within equipment if circuitry is not well isolated. This will cause a continuous “hum” or “buzz” background noise. Also inverter may cause interference to TV signals.
Page 10
MODEL SPEC SSI006UK SSI007UK SSI008UK SSI009UK SSI010UK SSI011UK 10.8- 10.8- VOLTAGE 21.6-31Vdc 21.6-31Vdc 10.8-15.5Vdc 21.6-31Vdc 15.5Vdc 15.5Vdc EFFICIENCY Over 80% Efficiency POWER TYPE Open & Seal Lead Acid Battery, Regulated DC Alternator CONTINUOUS 1000W 1000W 1500W 1500W 2500W 2500W POWER SURGE 200% of Continuous Power for 2 sec to help starting up POWER...