Access control proximity reader with bluetooth (11 pages)
Summary of Contents for Genie FR01W
Page 1
Facial Recognition Reader with 7” LCD Screen and 2x 2MP Cameras FR01W User Manual Please read these instructions carefully before operating the unit and keep for further reference.
Chapter 1 introduction Apparatus shape Model Black/Silver: FR01W Application It is suitable for office areas, hotels, access gates, office buildings, schools, shopping malls, shops, communities, public services and management projects, etc. Feature Support for external HDMI large screen (only supports vertical screen);...
Support for live photo preservation when face recognition or stranger detection; Support public network and LAN deployment methods; Support HTTP interface interfacing; Support screen display content configuration; Support for recognition distance configurations. Specification FR01W - Facial recognition integrated terminal 6/ 34...
Page 8
FR01W Model size 7", full viewing angle, 170° IPS LCD screen Screen resolution 1024× 600 type RGB and infrared RGB and infrared serial number 02F8、02FA(discontinued) 01F8、01FA resolution 200WPixel 200WPixel aperture F2.4 F2.1 focal length 5.75mm 4.43mm White balance auto auto...
Page 9
interface Reset interface RESET hole on the back of the device Wired network 2.5mm terminal block 4P interface Face Detection Supporting detection and tracking of 5 people at the same time 1:N face Under the condition of 3% misidentification rate, the recognition recognition accuracy rate is 99.7%.
Installation steps 1. wiring instructions (take the power line as an example, other wiring and analogizing later) a) Strip the wire (using tools such as scissors) to expose the wire as shown. b) Press the orange button at each connector on the green bar to insert the wire end into the hole, then loosen the orange button to secure the wire as shown.
Page 13
the device will start normally; the device power adapter requires 12-16V, Be careful not to short the positive and negative wiring, otherwise the device will not start. If you do not need to install the device on the wall, you can directly refer to step 6. After the device is powered on, start using the device.
Page 14
4. According to the mounting position of the bracket, insert the green plug of the connected cable out of the outlet hole. If you need to reset the cable and HDMI cable, please pass it out from the outlet hole at this step. 5.
Page 15
6. Insert the green interface into the connector on the back of the device。 7. Screw the countersunk screw into the bracket for two turns, then align the slot under the device with the hook under the bracket. Use a hexagon socket tool or a hex driver to tighten the countersunk screw in the direction of the arrow.
Chapter 3 wiring Material / Tool List Material/Tool Quantity Note Self-contained accessories include: 12V NF4000 Facial recognition adapter, wall mount bracket, expansion instrument + accessories tube, self-tapping screws, hex wrench, hexagon socket screws, etc. Exit button (optional) Use to exit When the power is off, the door is opened, Electromagnetic lock (optional) and when the power is turned on, the door...
3.4.2 Automatic door sensor head switch wiring diagram Precautions 1、Touch the cable inside the Exit button panel as far as possible from the center of the back of the panel. 21/ 34...
Page 23
2、In actual wiring, if the 12V power supply line of Keyking host does not use “dedicated power extension cable” and the distance is long, it will result in excessive cable equivalent resistance, which will be prone to abnormal phenomena such as insufficient terminal voltage (≤11V) and host.
Page 24
3、The device with a power adapter as shown in the figure, the total length is 1 meter, of which the power cable (weak power part) 40cm, the power line (strong power part) The power cable (weak power part) must not be extended by more than 2 meters. Otherwise, the voltage at the host terminal of the device will be insufficient, and repeated restarts and crashes will occur.
Page 25
If other adapters are used, such as 9V, 1A, the voltage is too low and the current is too small, which will cause the device to restart repeatedly. The cable used should not be too thin (such as a thin wire). It is recommended to connect multiple strands of the same cable or use a thick copper core cable to ensure a voltage >11V.
Chapter 4 System setting NF4027P setting Set ip in NF4027p, make sure it is in the same IP segment with sphinx Sphinx4.4 setting Communication configuration 25/ 34...
Page 28
NF4027P Facial recognition user manual V1.00 As shown in the figure below, click search, fill the IP segment that covers the NF4027P. 27/ 34...
Chapter 5 Registered Click 【Add a Personnel】 to pop up the following window and click to add new one. In 【Basic Information】,fill in the ID, name, department information 29/ 34...
Page 31
In 【Card】 , tick the 【Use Access Card】 , obtain the card number through the card issuer or card reader, or manually enter the card number (card number = face recognition terminal card) 30/ 34...
Page 32
in【Access Level】,tick the security groups 31/ 34...
Page 33
In 【Face Info】 , check Use face recognition under NF1000, and check the face recognition device in the 【Device Name】box. 32/ 34...
Chapter 6 Test In 【Monitor】 ,choose【Photo Viewer】,then 【Face Recognition Viewer】,we can see the registered face and the new coming face . If the recognition is Successful , the state is true. 34/ 34...