Feature Menus; Menu 1 - Vehicle Integration - Directed Electronics Viper 4704 Installation Manual

Keyless entry and remote start, responder lc3
Table of Contents

Advertisement

Feature Menus

Default settings are Opt. 1 (in bolder type). New features are bold with grey background.

Menu 1 - Vehicle integration

Menu
Feature
Item
1
System Locking Mode
2
Panic Mode
3
Horn Function
4
Ign-controlled locks
5
Door Lock Pulses
6
Door Lock output duration
7
2nd Unlock
8
Comfort Closure
9
Hood Switch Type
10
Door Switch Type
11
Remote Button unlock (Ign off)**
* The H2/6 Green or the H2/12 Violet wire must be connected for this feature.
** Not available with 1- way remote.
1. System Locking mode
1. Active: the transmitter must be used to lock the system
2. Passive Locking: after exiting the vehicle the system will automatically lock the doors
3. Auto re-locking: if the vehicle is not entered after receiving a unlock command, the system will auto-
matically re-lock the doors
2. Panic Mode
1. On: the Panic output can be activated at any time
2. Ign Off Only : the Panic output can be activated only when the ignition is off
3. Off: the Panic output is defeated
3. Horn Duration
1. - Opt 4. 20 - 50 sec: sets the horn output duration with Panic mode at 30 seconds
2. Off: turns the horn output off and with Panic mode at 60 seconds
4. Ign-controlled Locks
1. No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned on/off
2. Lock & Unlock: the door lock & unlock output will activate when ignition is turned on & off
3. Lock Only: the door lock output will activate when ignition is turned on
4. Unlock Only: the door unlock output will activate when ignition is turned off
5. Door Lock Pulses
1. Single: the door lock & unlock outputs will pulse once
2. Double Unlock only: the unlock output only will pulse twice
© 2011 Directed Electronics. All rights reserved.
Opt. 1
Opt. 2
Active Locking
Passive Locking
On
Ign Off only
Confirmation
Confirmation
Honk (30 ms) &
Honk (20 ms)
Panic
& Panic
No Ign- lock-
Lock & Unlock
ing
Single
Double Unlock
Only
0.8 sec.
3.5 sec.
2nd unlock on/
2nd unlock on/
Ign-control af-
Ign-control with
first unlock
ter first unlock
No Comfort
Comfort Closure
1
Closure
Normally Open
Normally closed
Normally
Normally
Open
Closed
Off
On
Opt. 3
Opt.4
Auto Re-
locking*
Off
Confirmation
Confirmation
Honk (40 ms)
Honk (50 ms) &
& Panic
Panic
Lock Only
Unlock Only
Double Lock
Double Lock &
Only
Unlock
0.4 sec.
Comfort
Closure 2
Opt. 5+
Confirmation
Honk Off -
Panic Only
(Pulsed)
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clifford 470.4xPython 474

Table of Contents