Brake Chopper

5 Brake Chopper Mounting

5.1 Installation Conditions

The brake chopper must be vertically installed.
If one brake chopper is arranged above another, make sure the upper limit of air
temperature (50 ℃) into the inlet is not exceeded. An air guide is recommended
between the brake choppers to prevent the rising hot air being drawn into the
upper brake chopper if the upper limit of air temperature is exceeded.
Fig. 5-1: Mounting distance and arrangement
d
: Distance horizontal = 0 mm
hor
d
: Minimum top distance = 125 mm
top
d
: Minimum bottom distance = 125 mm
bot
1: Air inlet at brake chopper
2: Air inlet at control cabinet
3: Brake chopper
4: Air outlet at brake chopper
5: Heated air conveying direction
6: Air guide in control cabinet
7: Fan in control cabinet
8: Discharge of heated air