  • Page 2: Table Of Contents

    CONTENTS PAGE 1. SAFETY ..................................... 2. INSTALLATION AND MAINTENANCE INSTRUCTION MANUAL ................2.1 IMPORTANT F400 ..............................3. EC APPROVAL AND CORRECT USE OF THIS FAN ...................... 4. APPLICATIONS ................................5. FAN RECEPTION AND VERIFICATION .......................... 6. TRANSPORT AND STORING ............................7.
  • Page 3: Safety

    1. SAFETY The following symbols refer to dangers or give advice for safe operation Attention! Danger! Safety advice! Danger from electric current or high voltage! Crush danger! Danger! Do not step under hanging load! Important information Fans are produced in accordance with the latest technical standards and our quality assurance programme, which includes material and function tests, ensuring that the final product is of a high quality and durable.
  • Page 4: Installation And Maintenance Instruction Manual

    DO NOT INSTALL THE FAN BEFORE READING THESE INSTRUCTIONS. KEEP THEM FOR FUTURE APPARATUS MAINTENANCE OR HANDLING. 2.1 IMPORTANT F400 All F400 fans (400°C/2h) manufactured by Woods Air Movement and described in this manual are approved according to the UNE EN 12101-3/2002 standard in order to comply with the CTE 2006.D.C.B97106CEE directive (FORMERCPI196),andarethereforespecificallyrecommendedforemergencysmokeextractionincaseoffire.
  • Page 5: Applications

    VERIFICATION, PLEASE CONTACT US. The selected fan model should never be used to convey gas of a composition or temperature other than that specifiedbyWoodsAirMovement,norshoulditoperateinsurroundingswithdifferentconditionstothose indicated IN THE ATEX RANGE OF FANS. THE TEMPERATURE REACHED BY ANY OF THE SURFACES HAS BEEN CALCULATED TO ENSURE THE PRESENCE OF THE SPECIFIED GASES WILL NOT POSE A RISK OF IGNITION.
  • Page 6: Our Product Guarantee

    8.1 WARRANTY PERIOD Woods Air Movement fans have a 1-year guarantee from date of purchase (always keep the invoice). The stated warranty period will expire after a year, even if the fan has not been installed or used immediately after its purchase from Woods Air Movement.
  • Page 7: Voltage And Frequency

    IN INTERMEDIATE CONNECTIONS, BOXES THAT COMPLY WITH THE F400 DEMANDS MUST BE USED (CAREFULLY READ THE F400 MOTOR MANUAL INSTRUCTIONS). CABLES CATALOGUED AS “FLAME RESISTANT” WHICH DON’T GUARANTEE A F400 SERVICE ARE NOT SUITABLE FOR THIS FUNCTION. WOODS AIR MOVEMENT RECOMMENDS VS OMERIN BRAND CABLES WHICH HAVE BEEN PROPERLY TESTED WITH OUR FANS.
  • Page 8: Sound Level

    9.10 PROTECTION AGAINST INVOLUNTARY ACCIDENTS Through Woods Air Movement, products (accessories) are available that protect the rotating body (propeller or turbine) in every fan model, according to UNE EN 294. The installer or end user must request and install these products to protect accesses to the interior of the fan that remains open, accessible and not connected to a duct.
  • Page 9: Fan Maintenance

    With wIn dual and only in emergency applications: It is recommended that the motor is replaced every 16,000 hours of operation. F400 MOTORS USED FOR REPLACEMENT IN APPROVED FANS MUST BE AUTHORISED BY WOODS AIR MOVEMENT. EVEN IF THE REPLACED MOTOR IS APPROVED, IT MAY HAVE NO VALIDITY WITH THIS PARTICULAR FAN.
  • Page 10: Wiring Diagram

    11. WIRING DIAGRAM 1 PHASE 3 PHASE...
  • Page 11: Ce Marking

    12. CE MARKING 12.1 DECLARATION OF CONFORMITY We hereby declare under our sole responsibility that Woods Air Movement products comply with the requirements of the applicable EC / EU directives. The declaration of conformity for compliance with the applicable EC / EU directives exclusively refers to fans that are connected according to the operating instructions and operated independently with sinusoidal power supply.
  • Page 12: Ec Declaration Of Incorporation

    Notes: Fläkt Woods fans are driven by AC induction motors which are inherently compliant if supplied with a truly sinusoidal AC supply. Where the fan motor is supplied via an inverter or other electronic control, verification of its compatibility together with cabling should be Fläkt Woods fans are driven by AC induction motors which are inherently compliant if supplied with a truly sinusoidal AC supply.
  • Page 13 Notes...
  • Page 14 Notes...
  • Page 16 Woods Air Movement delivers smart and energy efficient Air Movement and Fire Safety solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than fifty years of accumulated industry application experience.

This manual is also suitable for: