Model 6303 & 6302
Zoned Comfort Control
®
Safety & Installation Instructions
READ AND SAVE THESE INSTRUCTIONS
61001212 B2206667E 2.19
English 1

Advertisement

Table of Contents
loading

Summary of Contents for Aprilaire Zoned Comfort Control 6302

  • Page 1 Model 6303 & 6302 Zoned Comfort Control ® Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61001212 B2206667E 2.19 English 1...
  • Page 2: Table Of Contents

    SAFETY INSTRUCTIONS ......... . 2 Read this installation manual before beginning installation of the Aprilaire®...
  • Page 3: Specifications

    SPECIFICATIONS INPUT RATINGS FIGURE 1 – ZONE PANEL DIMENSIONS IN INCHES (mm) Voltage: 18-30VAC 50/60 Hz MAXIMUM CURRENT Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F Zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire 9.66 (245)
  • Page 4: Zone Panel Layout

    ZONE PANEL LAYOUT TERMINALS FIGURE 2 – ZONE PANEL LAYOUT 1. HVAC – HVAC connection 2. ZONE 1 THERMOSTAT – Thermostat connection 3. ZONE 2 THERMOSTAT – Thermostat connection 4. ZONE 3 THERMOSTAT (6303 only) – Thermostat connection 5. DAMPER 1 – Zone 1 damper connection 6.
  • Page 5: Installation

    INSTALLATION MOUNTING 1. Separate the zone panel cover from the FIGURE 3 FIGURE 4 – MOUNTING HOLE LOCATIONS base. See FIGURE 3. 2. Use the base as a USE TWO SCREWS WHEN template to drill ATTACHING TO A WALL STUD mounting holes.
  • Page 6: Wiring

    WIRING WARNING FIGURE 6 – WIRE TIE MOUNTS 120 volts may cause serious injury from electrical shock. Sudden operation may cause serious injury from moving parts. Leave power disconnected until installation is complete. Follow these steps for all system connections. Wiring will vary depending on equipment.
  • Page 7: Select And Wire The Transformer To The Control Panel

    SELECT AND WIRE THE TRANSFORMER TO THE CONTROL PANEL 1. Note: The HVAC equipment transformer cannot be used for power. A separate transformer should be used to FIGURE 7 – TRANSFORMER power the zone panel, thermostats and dampers. 2. Wire 24VAC from transformer to the POWER, R and C terminals (see FIGURE 7).
  • Page 8: Zone Damper Wiring

    ZONE DAMPER WIRING • Run 2-conductor thermostat wire for spring return dampers (normally open or normally FIGURE 8 – NORMALLY OPEN / POWER CLOSE DAMPERS closed). • Run 3-conductor thermostat wire for power open/power close dampers. • Multiple dampers for the same zone can be wired in parallel as shown in FIGURES 8 &...
  • Page 9: Discharge Air Temperature Sensor (Included)

    DISCHARGE AIR TEMPERATURE SENSOR (INCLUDED) • Wire the discharge air temperature sensor Model 8052 to the “DAT” terminals as FIGURE 10 – DISCHARGE AIR TEMPERATURE SENSOR shown. See FIGURE 10. • Maximum distance of the sensor from the zone panel is 300 feet. •...
  • Page 10: Sequence Of Operation

    SEQUENCE OF OPERATION The 6303/6302 zone panel is for single stage heat pump applications, with a single stage of auxiliary heat. The zone panel is a heat call priority system with automatic heating/cooling changeover after 20 minutes of operation. If two opposing (heating/cooling) thermostat calls exist while the system is idle, the heating call will be satisfied first.
  • Page 11: Limited Warranty

    WARRANTY REGISTRATION Visit us online at www.aprilaire.com to register your Aprilaire product. If you do not have online access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name and address to: Research Products Corporation, P.O. Box 1467, Madison, WI 53701.
  • Page 12 AprilairePartners.com P.O. Box 1467 Madison, WI 53701-1467 800.334.6011 F: 608.257.4357 ©2019 Aprilaire – Division of Research Products Corporation 12 English...