Instructions
Before installing or servicing this device
please read and take the 'Safety precautions'
into account. These can be found on the
backside of this installation guide.
Step
Remarks
1.
DC output
Default output is 13.2 V.
2.
Shield & earth
Connect shield and earth wire at the same time to the same terminal.
3.
AC mains input
Make sure the AC mains input is still disconnected at this point.
4.
Strain relief & cover
Use the available provisions to secure all cables.
5.
Power ON
Make sure the protection cover is put back over the terminals.
Wiring specifications
Failure to comply with the wiring specifications may result in
malfunction and/or dangerous situations.
Purpose
Specification
A. AC mains input wiring
3 x 0.75 mm², earth connection, max. 2 m
B. DC output wiring
2 x 0.5 mm
5
AC mains input
Protection cover
3
L
Conductors connected to the screw
terminals must be fitted with a ring,
crimped lugs, etc. so that reliance is not
placed upon the screw alone.
shielded, max. 5 m
2
2
1
N
-V
+V
Voltage adjuster
-
+
Power LED
DC output
DC output
1
2 x 0.5 mm
2
shielded, max. 5 m
Remove the protection cover from the
terminals before wiring.
Shield & earth
The protective earth wire should be the
2
last to disconnect in the event of an
inadvertent pull on the power cord.
Earth wire
Shield
(green-yellow)
AC mains
AC mains input
3
3 x 0.75 mm², earth connection, max. 2 m
Make sure that the AC mains (230-240 VAC)
is NOT connected!
L
N
Live
Neutral
(brown)
(blue)
AC mains
Strain relief & cover
4
Make sure all cables are properly secured
and the protection cover is placed back
over the terminals.
Power ON
5
Make sure to close the enclosure before
connecting the AC mains.
If powered devices are not working properly
please check if the DC output is 13.2 V.
The DC output can be adjusted with the
Voltage adjuster.
A
-V
+V
GND
Vin
DC output
-V +V
DC output
B
-V +V