SOLE EUROSTAR ECO BF INOX Series Installation And Operation Manual

SOLE EUROSTAR ECO BF INOX Series Installation And Operation Manual

Hygienic combi tanks

Advertisement

Quick Links

SOLE S.A.is the inventor of the closed circuit
Solar Water Heater.
SOLE S.A. holds numerous prizes and
environmental dis nc ons, contribu ng
with its products to the improvement of
environment in all 5 con nents.
S O L E S.A.
SOLAR APPLIANCES MANUFACTURER
Le tron 1 & Laikon Agonon, 136 71 Acharnai - Athens - Greece
Tel.: +30210 2389500
Fax: +30210 2389502
Email: export@sole.gr
www.
sole
.gr
www.
eurostar-solar
.com
Advantages
 
Maximizes efficiency
  No need for refilling the solar loop
  Best aesthe c results. Low version
with hidden tank available
  Easy to install
  Minimum maintenance needed
  Anode protec on
Commitment
to the Environment
Since its founda on in 1974 SOLE S.A. has been
commi ed to the protec on of the environment
and the reduc on of CO emission.
2
Quality Solar Systems
Solar Water Heater
T
he new series of thermosiphon
systems EUROSTAR ECO, have
been designed in order to cope with
the demands of any market all over
the world specializing in very hot
climates without the need for
refilling the solar circuit.
The EUROSTAR ECO solar
water heater is manufactured
in compliance with the
Interna onal Standards for
Quality Assurance ISO
9001:2008, is tested according
to interna onal standards
EN12976‐1‐2.
Durable
withstanding 22,5 bar pressure!!!
Discrete
with a low version (hidden tank) for
preserving architectural designs.
The collector's performance
and reliability is tested
according to EN 12975‐2.
The system has been granted
with the Solar Keymark
Cer ficate.
www.
eurostar-solar
.com

Advertisement

Table of Contents
loading

Summary of Contents for SOLE EUROSTAR ECO BF INOX Series

  • Page 1   Anode protec on refilling the solar circuit. Commitment to the Environment Since its founda on in 1974 SOLE S.A. has been commi ed to the protec on of the environment and the reduc on of CO emission. The EUROSTAR ECO solar...
  • Page 2 71.00 Aluminum profile. Free of screws and rivets. FRAME The new thermosiphon system of SOLE is also available in low height in three sizes, 150, 200 and 300ltr. COVER Tempered low iron prisma c glass 3.2 mm. 90,5% transmission. SEALING Acrylic foam ‐...
  • Page 3 Minimum maintenance needed Long durability Commitment to the environment Since its foundation in 1974 SOLE S.A. has been committed to the protection of the environment and the reduction of CO2 emission. SOLE S.A. holds numerous prizes and environmental distinctions, contributing with its products to the environment in all 5 continents.
  • Page 4 The backup electric heater ensures hot Solar Station Pump Control Unit water even in very cloudy days. Cold Water Inlet SOLE’s Solar Systems are manufactured in compliance with FORCED CIRCULATION KITS the International Standards for Quality Assurance ISO 9001:2015. MODEL...
  • Page 5 HYGIENIC COMBI TANKS series SOLE BF INOX vertical models 500, 800, 1000, 1500 L SOLE BF-2 INOX - with two coils SOLE BF-1 INOX - with one coil SOLE BF-0 INOX without coil INSTALLATION and OPERATION MANUAL Version 0.1...
  • Page 6: Table Of Contents

    CONNECTING OF RELIEF VALVE TO WATER TANK..........11 TECHNICAL PARAMETERS TO HYGIENIC COMBI TANK ........12 4.1. SOLE BF-0 INOX - without coil................12 4.2. SOLE BF-1 INOX - with one coil................14 4.3. SOLE BF-2 INOX- with two coils................16 TRANSPORT AND PACKAGING................18...
  • Page 7: Instructions To Installer

    INSTALLATION and OPERATION MANUAL • safety during installation - personal protective equipment Use only original parts. Dear Customers, We strongly hope that the appliance you have bought from us will contribute 1.1. Requirements to Water Tank to creating comfort at you homes and installation room decreasing the energy expenditure.
  • Page 8: Description On Hygienic Combi Tank

    – 90 angle degrees. SOLE BF-0 INOX models, the heat source is an electric heater. SOLE BF-1 INOX models have a built- in heat exchanger (coil type) designed to connect to a solar installation or boiler. Option for installation of an electric heating element.
  • Page 9: Electric Heating Element

    INSTALLATION and OPERATION MANUAL 2.3. Electric heating element. The connection of the electric heating element to the electric power supply must be done by a Outlet connection of electric heating qualified electricians. element 1 ½“ : When connect heating element to the electric network, 3000W/230V;4500W/230V;...
  • Page 10 INSTALLATION and OPERATION MANUAL...
  • Page 11: Thermostat

    INSTALLATION and OPERATION MANUAL 2.4.Thermostat sheme 1 TECHNICAL CHARACTERISTICS The thermostat may be adjusted by the Temperature range – regulation- 0°C ÷ user within the range 30°С ÷ 80°С, and the 90°C; thermal protection would go off in case limit - 90°C ÷ 110°C; the water reaches 95°С.
  • Page 13 INSTALLATION and OPERATION MANUAL C-1LIM.:0,5A/250V~; C2LIM.:10(2,5)A/250V~; Terminal – circuit breaker or switch-on contacts. Switch-on action – 2B. Place of installation – normal. Type of wire – M20 x 1.5. WARNING ! installation operations, including manual adjustments, must be fulfilled by a qualified sheme 4 specialist following all safety conditions.
  • Page 14 INSTALLATION and OPERATION MANUAL NOTE: See Scheme 6. TEMPERATURE ADJUSTMENT To close the front part, the cartridge (see Scheme 8) opening must align with the coupling of the adjustment knob. A – Reset button (only for TLSC) B – Knob for temperature adjustmentct CONNECTION (Scheme 7) LIMITATION...
  • Page 15: Connecting Of Relief Valve To Water Tank

    INSTALLATION and OPERATION MANUAL 3. CONNECTING OF RELIEF VALVE TO WATER TANK 3.1. Connecting of Buffer tank. Heating system Safety (relief) pressure valve Heat carrier inlet 2. Connecting of Stainless HYG coil. Stop (Shut-off) valves should never be installed between a safety (relief) valve and the tank.
  • Page 16: Technical Parameters To Hygienic Combi Tank

    INSTALLATION and OPERATION MANUAL 4. TECHNICAL PARAMETERS TO HYGIENIC COMBI TANK SOLE BF-0 INOX 4.1. - without coil SOLE BF-0 SOLE BF-0 SOLE BF-0 SOLE BF-0 500 INOX 800 INOX 1000 INOX 1500 INOX Capacity 1000 1500 Capacity of water tank DHW / Buffer tank...
  • Page 17 INSTALLATION and OPERATION MANUAL SOLE BF-0 SOLE BF-0 SOLE BF-0 SOLE BF-0 500 INOX 800 INOX 1000 INOX 1500 INOX Boiler heat carrier outlet С1, mm ”/150 ”/170 ”/170 ”/235 Boiler heat carrier outlet С2, mm ”/150 ”/170 ”/170 ”/235...
  • Page 18: Sole Bf-1 Inox - With One Coil

    INSTALLATION and OPERATION MANUAL 4.2. SOLE BF-1 INOX - with one coil SOLE BF-1 SOLE BF-1 SOLE BF-1 SOLE BF-1 500 INOX 800 INOX 1000 INOX 1500 INOX Capacity 1000 1500 Capacity of water tank DHW / Buffer tank L1/L2...
  • Page 19 INSTALLATION and OPERATION MANUAL SOLE BF-1 SOLE BF-1 SOLE BF-1 SOLE BF-1 500 INOX 800 INOX 1000 INOX 1500 INOX Boiler heat carrier outlet С1, mm ”/150 ”/170 ”/170 ”/235 Boiler heat carrier outlet С2, mm ”/150 ”/170 ”/170 ”/235...
  • Page 20: Sole Bf-2 Inox- With Two Coils

    INSTALLATION and OPERATION MANUAL 4.3. SOLE BF-2 INOX - with two coils SOLE BF-2 SOLE BF-2 SOLE BF-2 SOLE BF-2 500 INOX 800 INOX 1000 INOX 1500 INOX Capacity 1000 1500 Capacity of water tank DHW / Buffer tank L1/L2...
  • Page 21 INSTALLATION and OPERATION MANUAL SOLE BF-2 SOLE BF-2 SOLE BF-2 SOLE BF-2 500 INOX 800 INOX 1000 INOX 1500 INOX Boiler heat carrier outlet С1, mm ”/150 ”/170 ”/170 ”/235 Boiler heat carrier outlet С2, mm ”/150 ”/170 ”/170 ”/235...
  • Page 22: Transport And Packaging

    INSTALLATION and OPERATION MANUAL TRANSPORT AND PACKAGING 6. RECYCLING AND WASTE DISPOSAL Submit all packaging material for recy- We recommend to transport the water cling according to the local regulations and tank to the installation site in its packaging requirements. placed on the pallet, and stretch foil.
  • Page 23 ISO 9001 BUREAU VERITAS Certification SOLE S.A. Λαϊκών Αγώνων & Λεύκτρων 13671, Αχαρναί, Αττική GREECE...

Table of Contents