Dcf77; Ready Relay - Bosch PAVIRO PVA-4CR12 User Manual

Hide thumbs Also See for PAVIRO PVA-4CR12:
Table of Contents

Advertisement

PAVIRO Controller
6.8

DCF77

The top half of the control port has an input for the radio receiver of the DCF77 signal.
Observe the delivered documentation when connecting a 3
controller.
Recommended connecting cable: shielded flexible stranded wire, LiY, 0.5 mm².
6.9

Ready relay

The lower half of the control port has a potential-free READY changeover contact. This
changeover contact signals to other devices that the controller is ready for operation or
indicates faults in the system. The following table shows the possible statuses of the ready
contact.
Recommended connecting cable: shielded flexible stranded wire, LiY, 0.5 mm².
Status
Ready for operation (=
ready)
Not ready
Table 6.6: READY contact
Bosch Security Systems
Switch position
User manual
Connection | en
rd
party DCF receiver to the
Description
The voltage supply is functioning,
the boot process of the device has
completed, and there are no faults
in the system. The relay has been
activated.
The voltage supply is off/interrupted
or the boot process of the device
has not yet completed, or there is a
fault in the system. The relay has
dropped/is without power.
2022-11 | 07 | F01U306900
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents